![Intellinet 560931 User Manual Download Page 46](http://html1.mh-extra.com/html/intellinet/560931/560931_user-manual_2074478046.webp)
46
Indicates the index of the entry. The range is from 1 to 65535.
Data Source
Indicates the port ID to be monitored. If in a stacked switch, the value must add 1000* (switch ID-1); for
example, if the port is switch 3 port 5, the value is 2005
Buttons
Add new entry:
Click to add a new community entry.
Save:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved values.
RMON
History
Configuration
Configure the RMON History table on this page. The entry index key is ID
.
Delete
Check to delete the entry. It will be deleted during the next save.
ID
Indicates the index of the entry. The range is from 1 to 65535.
Data Source
Indicates the port ID to be monitored. If in a stacked switch, the value must add 1000* (switch ID-1); for
example, if the port is switch 3 port 5, the value is 2005.
Interval
Indicates the interval in seconds for sampling the history statistics data. The range is from 1 to 3600; the
default value is 1800 seconds.
Buckets
Indicates the maximum data entries associated with this History entry stored in RMON. The range is from
1 to 3600; the default value is 50.
Buckets Granted
The number of data shall be saved in the RMON.