Overview AT Commands
INSYS WLAN serial 2.1
Command
Description
AT#TLP=”<password
>”
Password for remote configuration
AT#TLP="password"
- in quotation marks! – maximum length: 8 characters.
The entry is case sensitive. The default setting is "insys".
The user name and the Telnet port are determined with
AT#TLU
and
AT#TEL.
This setting is immediately stored in the permanent memory (independent
from the command
AT&W
).
AT#TLU=“<name>“
User name for remote configuration
AT#TLU="name"
- in quotation marks! – maximum length: 8 characters. The
entry is case sensitive. The factory setting is "insys".
The password and the Telnet port are determined with
AT#TLP
and
AT#TEL.
This setting is immediately stored in the permanent memory (independent
from the command
AT&W
). It will only take effect after a restart.
ATT
Select TCP mode
For the next connection
ATT
selects the TCP mode. This setting applies to
ATD
commands without a specific protocol (e.g.
ATD192.168.100.200:1234
or
for incoming calls.
ATU
Select UDP mode
For the next connection,
ATU
selects the UDP mode. This setting applies to
ATD
commands without a specific protocol (e.g.
ATD192.168.100.200:1234
or
for incoming calls.
AT*U<n>
Select data format
AT*U
sets the data format at the serial interface.
The following data formats (data bits, parity, stop bits) are supported:
AT*U0
8N1
(default)
AT*U1
7E1
AT*U2
7O1
AT*U4
7E2
AT*U5
7O2
AT*U6
7N2
AT*U7
8E1
AT*U8
8O1
AT*U9
8N2
ATV<n>
Select message format (short or long format)
ATV
sets the format for responses.
ATV0
Outputs message numbers (table see Chap. 5)
ATV1*
The messages are displayed in plain text.
86
Summary of Contents for WLAN 2.1
Page 1: ...Manual INSYS WLAN serial 2 1 Sep 10...
Page 2: ......
Page 93: ...INSYS WLAN serial 2 1 Declaration of Conformity 19 Declaration of Conformity 93...
Page 98: ......