Initial Operation
INSYS WLAN serial 2.1
The message "read settings" appears in the status bar of HSComm WLAN.
bar of HSComm WLAN.
5.
Select the role "Slave".
6.
the channel number 6.
8.
Select "128 bit WEP" encryption as security option.
The WPA encryption is not available in ad-hoc mode.
key on the first position of the key list (13 bytes in hexa-
he list is also considered for encryption. The key
must be entered for all devices in the WLAN
on the same position in the
n communicate with each
other.
10.
Check the key for type errors.
The message "read settings" appears in the status
3.
Click on the "WLAN" tab.
4.
Select the "adhoc" mode.
Enter for "channel"
7.
Enter the SSID (the network name) of your WLAN.
Observe case sensitivity for the SSID!
9.
Enter your WEP
decimal notation).
The position of a key in t
key list
that all devices use the same key and ca
11.
Click on Send.
HSComm WLAN transfers the values and the message "send settings" ap-
pears in the status bar.
The "RX/TX" LED is blinking during the process.
The message "settings sent" appears.
12.
Click OK in the message.
The "RF Link" LED at the device is illuminated and the "Signal" LED is illumi-
nated or blinking. This means that the INSYS WLAN serial 2.1 is connected
to the access point.