INSYS WLAN serial 2.1
Functions
The INSYS WLAN serial 2.1 accepts incoming TCP connections after the first attempt as
default setting.
Configuration with HSComm
Set the
port
as well as the
protocol
for the incoming connections on the
"Network" tab in the "IP Settings" panel (Figure 7, page 45, position 1).
The
automatic answer
can be enabled on the "Network" tab in the "Connec-
tion" panel (Figure 7, page 45, position 4).
Configuration with AT commands
In order to
configure the port
, use the com-
mand
Parameter <n> is the port number.
AT#PORT=<n>
In order to
configure the TCP protocol
, use the
command
ATT
In order to
configure the UDP protocol
, use the
command
ATU
In order to configure the
number of "ring
tones" until accepting the connection
, use the
command
Parameter <n> is the number of ring tones.
ATS0=<n
>
In order to accept a connection immediately,
use the command
ATS0=1
In order to accept a connection only "manu-
ally" using the
ATA
command, use the com-
mand
ATS0=200
In order to accept no connection immediately,
use the command
ATS0=0
In order to enable idle connection control, use
the command
<n> is the time in seconds, maximum 255 sec-
onds
AT#DTC=<n>
In order to disable idle connection control, use
the command
AT#DTC=0