INSYS WLAN serial 2.1
Overview AT Commands
Command
Description
AT#GW=<IP ad-
dress>
Set gateway address
The standard gateway is set with
AT#GW
. This setting is used by remote IP ad-
dresses, which can only be accessed by routers, not directly.
IP packets, which cannot be sent to the local network (defined by
AT#IP
and
AT#NM
), are sent using the address set by
AT#GW
for forwarding.
AT#GW
is used in connection with
AT#NM
to establish a connection via a router.
If a router is used,
AT#GW
and
AT#NM
must be set to enable a data connection
via the router.
Factory setting:
AT#GW=0.0.0.0
IP address, gateway and network mask must be coordinated in the local net-
work segment.
The setting can be queried with
AT#GW?
.
This setting is immediately stored in the permanent memory (independent
from the command
AT&W
). It will only take effect after a restart.
ATH
Dummy command
Command with an optional parameter without effect implemented for com-
patibility to the modem – response “OK”. When the connection is interrupted
with the sequence “+++”, the module will terminate the connection.
The INSYS WLAN serial 2.1 does not support any online command mode.
ATI<n>
Display of the module identification
ATI0
Displays the device type („
WLAN 802.11b/g
“)
ATI3
Displays the version number and the date when the firm-
ware was created
ATI4
displays an ID string and the version number
AT*I<n>
Querying the alarm input
0
Input is connected to GND and therefore activated
1
Input is open and therefore not activated
75
Summary of Contents for WLAN 2.1
Page 1: ...Manual INSYS WLAN serial 2 1 Sep 10...
Page 2: ......
Page 93: ...INSYS WLAN serial 2 1 Declaration of Conformity 19 Declaration of Conformity 93...