Triton Go Product Manual |
Wiring and Connections
INGENIA | 05/29/2017
66
Number of inputs
3
ESD capability
IEC 61000-4-2 (ESD) ± 30 kV (air), ± 30 kV (contact)
Voltage range
0 ~ 5 V
Maximum voltage range
-0.5 ~ 5.5 V
Maximum recommended working
frequency
1 kHz
1st order filter cutting frequency (-3dB)
160 kHz
Sampling frequency
10 ksps
Type of sensors
Open collector
Logic output
Push-pull output
Pull-up resistor value
1 kΩ (The pull-up is activated only when the drive is
configured to use digital hall sensors)
Next figure shows the circuit model of the digital Halls inputs.
Digital and analog Halls
Digital halls input pins are shared with
The 1 k
Ω
pull-up resistors are disconnected when Analog-halls input is selected to prevent analog data
corruption.