Triton Go Product Manual |
Wiring and Connections
INGENIA | 05/29/2017
58
60
http://www.digikey.es/product-detail/en/3200881/277-5453-ND/349955
7.2.5 Power supply wiring recommendations
Wire section
The minimum wire section is determined by the current consumption and the allowed voltage drop across the
conductor. It is preferred to use
wide section stranded wires
to reduce impedance, power losses and ease the
assembly. Insulator size should not exceed 3.5 mm (connector pitch). Following table indicates recommended
wire sections:
Connection
Minimum wire size
Maximum wire size
Stranded wire (preferred)
0.5 mm
2
(20 AWG)
1.5 mm
2
(16 AWG)
Solid wire
0.5 mm
2
(20 AWG)
1.5 mm
2
(16 AWG)
Wire ferrules
For
low power applications
, it is recommended to use wire ferrules to prevent cable damage or wrong
contacts. For
higher power applications, direct cable connection is recommended
, since it provides lower
contact resistance. Due to the connector's size, the maximum allowed ferrule size is 0.5 mm
2
. Ensure the
insulator does not exceed 3.5 mm (connector pitch). Following table indicates recommended wire ferrules
for the Triton Go Servo Drive:
Manufacturer
Part number
Image
Description
Phoenix Contact
8 mm pin length,
0.5 mm
2
(20 AWG)