Triton Go Product Manual |
Signalling LEDs
INGENIA | 05/29/2017
49
56
http://doc.ingeniamc.com/display/EMCL/Error+management
57
http://www.can-cia.org/
LED
Colour
Meaning
SHUN
T
Blue
LED is turned on when the supply voltage is greater than the maximum voltage
configured
by the user.
FAULT
Red
LED is on when an error event has occurred and the drive is trapped in the
Fault
state
.
Find more about the Fault state in the
page.
6.2
CAN signalling LEDs (only TRI-x/48-C-C)
Two LEDs besides the CAN/EtherCAT connectors provide information about the CANopen communication
ERROR LED
and green one is
RUN LED
.
ERROR LED indicates the status of the CAN physical layer and errors due to missed CAN messages (sync, guard
or heartbeat). Next table the meaning of the ERROR LED states:
ERROR LED
state*
Concept
Description
Off
No error
Device is in working condition.
Single flash
Warning limit
reached
At least one of the error counters of the CAN controller has reached or
exceeded the warning level (too many error frames).
Double flash
Error control
event
A guard event (NMT-slave or NMT-master) or a heartbeat event
(heartbeat consumer) has occurred.
Triple flash
Sync error
The sync message has not been received within the configured
communication cycle period time out.
On
Bus off
The CAN controller is bus off.
RUN LED indicates the status of the CANopen network state machine. Next table shows the meaning of the RUN
LED states:
Configuration required
This signal will only work if the braking resistor output is configured as active.