Chapter 2 - Features set
User Manual
R5000 series - Web GUI
72
Read only
Enable/disable the read-only permission
Read/Write is the default value
Admin
Enable/disable the full access to the variables
E.g.: ability to reboot the device
Limited access is the default value
Privacy
Password
Set the privacy password
It is necessary when privacy is enabled for the required
security level
Privacy
Protocol
Set the encryption method for SNMP v.3: DES/AES128
Table 16 - SNMP Access
2.4.7.2. Traps
SNMP protocol operation requires a network agent instance to send asynchronous
messages (traps) whenever a specific event occurs on the controlled device (object).
InfiNet Wireless units have a built-in SNMP Traps support module (which acts as an
agent) that performs a centralized information delivery from unit internal subsystems
to the SNMP server. This zone focuses on SNMP Traps agent configuration.
In this section, you can view and edit the current SNMP traps settings. You can
clone, remove and clear target and traps by pressing the corresponding buttons:
SNMP traps
parameter
Description
Enable SNMP
Traps
Enable/disable to send SNMP traps
Agent IP
Set the IP address of the device which sends traps
Transport
Set the transport method
Two options are available:
-
“IP” - all SNMP traps are sent to the server specified
in the
“Destination” field below
-
“MINT Gateway” - this option should be used when
the SNMP server is located beyond a gateway that
acts as an SNMP agent for the whole MINT network
Gateway MAC
Set the MAC address of the gateway in your MINT
network (relay device)
if you selected “MINT Gateway”
option