Cheetah Pregius Camera with 10 GigE Vision Interface – User Manual
October 8, 2020
Page
54
of
170
Rev 1.0
Parameter Name Type
Value
Access Description
Strobe2Reference Enumeration
String
Exposure
Readout
Trigger
Num.
0
1
2
RW
Sets the reference event for
Strobe #2 signal.
Strobe2Enable
Enumeration
String
Off
On
Num.
0
1
RW
Enables or disables the Strobe #2.
Strobe2Width
Integer
Min: 1
Max: Depends on
CurrentFrameTime and
Strobe2Delay
RW
Sets Strobe #2 pulse duration in
microseconds.
Strobe2Delay
Integer
Min: 10
Max: Depends on
CurrentFrameTime and
Strobe2Width
RW
Sets Strobe #2 delay from the
reference, in microseconds.
1
LineSource
values (for outputs only):
ExposureStart
A short pulse indicating the beginning of the exposure
ExposureEnd
A short pulse indicating the end of the exposure
MidExposure
A short pulse indicating the middle of the exposure
ExposureActive
The output signal is active for the duration of exposure time
TriggerActual
Maps the input trigger pulse to the output with no delay
TriggerDelayed
Maps the input trigger pulse to the output with trigger delay
PulseGenerator
Maps the internal pulse generator waveform to the output
Strobe1
Maps the Strobe 1 signal to the corresponding external output
Strobe2
Maps the Strobe 2 signal to the corresponding external output
2
LineFormat
values:
NoConnect
The line is not connected
TriState
The line is currently in Tri-State mode (Not driven)
TTL
The line is currently accepting or sending TTL level signals
OptoCoupled
The line is opto-coupled
You can monitor the current logic level (1 or 0) of the signal on the selected input or output by
using the
LineStatus
parameter.
The