Opto-Isolated Output
Opto-isolated output is an optically isolated switch. There is no pull-up voltage on either contact.
An external pull-up voltage of up to 25 V is required for operation. Output is not polarity
sensitive. AC or DC loads are possible. The voltage across Contact 1 and Contact 2
must not
exceed 25 V and the current through the switch
must not
exceed 50 mA. ‘On’ resistance is less
than 5 Ohms.
OUT2 Open drain logic driver circuit:
OUT2 Low side load driver circuit:
V
S
– from 2.5 V to 25 V (DC or peak AC)
R2 – from 50 R to 500 R
I
L
– from 1 mA to 50 mA