Cheetah Pregius Camera with 10 GigE Vision Interface – User Manual
October 8, 2020
Page
56
of
170
Rev 1.0
Pulse Generator
The camera provides an internal pulse generator for generating a trigger signal. You can program
it to generate a discrete sequence or a continuous trail of pulse signals.
Parameter Name
Type
Value
Access Description
PulseGenGranularity
Enumeration
String
x1uS
x10uS
x100uS
x1000uS
Num.
0
1
2
3
RW
Sets the multiplication
factors of the Pulse
Generator where
x1 = 1 µS, x10=10 µS, etc.
PulseGenWidth
Integer
RW
Sets pulse width of Pulse
Generator where each unit
is equal to
PulseGenGranularity
.
PulseGenPeriod
Integer
RW
Sets pulse period of Pulse
Generator where each unit
is equal to
PulseGenGranularity
.
PulseGenNumPulses
Integer
Min: 1
Max: 65536
RW
Sets number of pulses to be
generated by Pulse
Generator.
PulseGenMode
Enumeration
String
Continuous
NumPulses
Num.
0
1
RW
Sets the mode of the Pulse
Generator.
PulseGenEnable
Boolean
RW
Enables Pulse Generator.
The pulse generator output
can be mapped to the
OUTPUT1 or OUTPUT2
output signals. It also can be
used as a trigger source.