The camera supports two inputs and two outputs (TTL and opto-isolated):
Input / Output #
Pin #
Description
Voltage/Current
Input 1
Pin 8 and Pin10 (Return) Opto-isolated
Voltage 3.3–24 V,
Current (min) 3.3 mA
Input 2
Pin 9 and Pin 11 (Return) TTL/LVTTL
Voltage 5 V (TTL) or 3.3 V (LVTTL)
Current (max) 2.0 mA
Output 1
Pin 7 and Pin 6 (Return)
TTL
Voltage 5.0 V (TTL)
Current (max) 8.0 mA
Output 2
Pin 12 and Pin 5 (Return) Opto-isolated
Voltage (max) 25 V
Current (max) 50 mA
You can map Input 1 or Input 2 to the camera trigger source by following the steps 1 – 6 in the
. In Step 4, set
TriggerSource
to
Line 1
(Input1) or
Line 2
(Input2)
respectively.
You can invert the input signal by using
LineInverter
setting in the Digital IO Control menu:
1.
Select Input1 or Input2 in
LineSelector
.
2.
Check the
LineInverter
box.
You can map one of nine signals to either Output 1 or Output 2 in the Digital IO Control menu:
1.
Set
LineSelector
to
Output1
or
Output2
.
2.
Select output signal in
LineSource
).
3.
You can invert the output signal by checking the
LineInverter
box.
4.
If applicable, enable a strobe and specify its width, delay, and reference (for more
information, refer to the section
Configuring the Strobe in Free-Running Mode
or
Configuring a Strobe in Trigger Mode