Cheetah Pregius Camera with 10 GigE Vision Interface – User Manual
October 8, 2020
Page
145
of
170
Rev 1.0
Configuration Memory
The camera has built-in configuration memory divided into six segments: Work Space, Factory
Space (Default), User Space #0, #1, #2 or #3. The Work Space segment contains the current
camera settings while the camera is powered up and operational. All camera registers are in this
space. You can program these registers and change the camera configuration through these
registers.
The Work Space is RAM based. All camera registers clear upon camera power-down. The Factory
Space (Default) segment is ROM based, write protected, and contains the default camera
settings. This space is available for read operations only. User Space #0, #1, #2 and #3 are non-
volatile, flash-based, and used to store up to four user defined configurations or User Sets. Upon
power up or software reset, the camera firmware loads the Work Space registers from the
Factory Space (Default), User Space #0, #1, #2 or #3 as determined by a User Set Default Selector
setting.
At any time, you can instruct the camera to load its Work Space with the contents of the Factory
Space, User Space #0, #1, #2 or #3 by first using the
UserSetSelector
to point to the desired User
Set then using the
UserSetLoad
command.
Similarly, you can instruct the camera to save the current Work Space settings into either User
Space #0, #1, #2 or #3 by using the User Set Selector to point to the desired User Set and then
using the User Set Save command:
1.
In the
User Set Control
menu, point to one of the User Sets to store your configuration using
the
UserSetSelector
.
2.
Execute
UserSetSave
command to save your configuration to the camera’s non-volatile
memory.
3.
Select your User Set (must be the same as in step 2) in
UserSetDefault
menu.
The camera loads and activates this User Set upon the next reset or upon power-up.