Configuring the Strobe in Free-Running Mode
In
free-running mode
, you can set the strobe pulse duration (
StrobeWidth
) and the delay
(
StrobeDelay
) with respect to the start of the exposure or the start of the readout period. The
strobe period is equal to the frame time. You can map a strobe to either Output 1 (TTL) or
Output 2 (opto-isolated).
Positioning the Strobe1 with a Reference to the Exposure Start
1.
In the DigitalIOControl menu, set
LineSelector
to Output1 (TTL) or Output2 (opto-isolated).
2.
Set
LineSource
to Strobe1.
The strobe is mapped to the output selected under
LineSelector
.
3.
If necessary, check the
LineInverter
box.
It inverts the output signal.
4.
Set
Strobe1Reference
to Start of Exposure.
5.
Set
Strobe1Enable
to On.
6.
If necessary, set
Strobe1Delay
.
Without a delay, the strobe occurs simultaneously with the start of exposure.
7.
Set
Strobe1Width
to a desired value.
Positioning the Strobe2 with a Reference to the Readout Start
1.
In the DigitalIOControl menu, set
LineSelector
to Output1 (TTL) or Output2 (opto-isolated).
2.
Set
LineSource
to Strobe2.
The strobe is mapped to the output selected under
LineSelector
.
3.
If necessary, check the
LineInverter
box.
It inverts the output signal.
4.
Set
Strobe2Reference
to Start of Readout.
5.
Set
Strobe2Enable
to On.
6.
If necessary, set
Strobe2Delay
.
Without a delay, the strobe occurs simultaneously with the start of exposure.
7.
Set
Strobe2Width
to a desired value.