Cheetah Pregius Camera with 10 GigE Vision Interface – User Manual
October 8, 2020
Page
53
of
170
Rev 1.0
Digital Input / Output Control
Digital Input / Output Control allows you to map camera’s inputs and outputs and configure
strobes.
Parameter Name Type
Value
Access Description
LineSelector
Enumeration
String
Input1
Input2
Output1
Output2
Num.
0
1
2
3
RW
Selects the physical line (or pin) of
the external camera connector or
the virtual line of the Transport
Layer to configure.
LineMode
Enumeration
String
Input
Output
Num.
0
1
RO
Returns the status of the physical
line used to input or output a
signal.
LineInverter
Boolean
RW
Controls the inversion of the
signal of the selected input or
output line.
LineStatus
Boolean
logic 1 – true
logic 0 – false
RO
Returns the current signal level on
the selected input or output line.
LineSource
Enumeration
String
Off
ExposureStart
ExposureEnd
MidExposure
ExposureActive
TriggerActual
TriggerDelayed
PulseGenerator
Strobe1
Strobe2
Num.
0
1
2
3
4
5
6
7
8
9
RW
Selects which internal signal to
output on the selected line.
LineSelector
must be set to
Output.
LineFormat
Enumeration
String
NoConnect
TriState
TTL
OptoCoupled
Num.
0
1
2
3
RO
Returns the current electrical
format of the selected physical
input or output line.
Strobe1Reference Enumeration
String
Exposure
Readout
Trigger
Num.
0
1
2
RW
Sets the reference event for
Strobe #1 signal.
Strobe1Enable
Enumeration
String
Off
On
Num.
0
1
RW
Enables or disables the Strobe #1.
Strobe1Width
Integer
Min: 1
Max: Depends on
CurrentFrameTime and
Strobe1Delay
RW
Sets Strobe #1 pulse duration in
microseconds.
Strobe1Delay
Integer
Min: 10
Max: Depends on
CurrentFrameTime and
Strobe1Width
RW
Sets Strobe #1 delay from the
reference, in microseconds.