![IFM O3M150 Software Manual Download Page 47](http://html1.mh-extra.com/html/ifm/o3m150/o3m150_software-manual_620524047.webp)
47
ifm Vision Assistant O3M
UK
Button
Name
Description
Ambient temperature
Set the frame rate of the device according to the ambient temperature:
●
85°C: Frame rate of 25 Hz
●
75°C: Frame rate of 33 Hz
●
65°C: Frame rate of 50 Hz
Always use the highest possible frame rate .
Application
Use the "Outdoors" setting if strong environmental influences are to be
expected in the application . The setting affects the:
● Filter signal quality (→ „10.3 Signal quality filter“)
● Noise reduction filter (→ „10.4 Noise reduction filter“)
Use the "Indoors" setting if insignificant environmental influences are to be
expected in the application . The setting affects the:
● Filter signal quality (→ „10.3 Signal quality filter“)
● Noise reduction filter (→ „10.4 Noise reduction filter“)
Visibility conditions
Activate the "Visibility conditions" setting if the visibility conditions are
often bad . The setting affects the:
● Filter signal quality (→ „10.3 Signal quality filter“)
● Spray detection (→ „10.5 Detection of spray/fog/dust“)
Dusty and foggy environmental conditions require stronger data
filtering . The "Visual conditions" setting reduces the device's
range .
Detection of soiling
Use the setting "Soiling detection" to set the sensitivity of the soiling
detection:
The setting affects the: Soiling detection
►
Click on [Next] .