ifm Vision Assistant O3M
144
Table of values:
Value
1
2
3
4
5
6
7
8
9
10
Analogue input of the controller [mA]
20
20
16
12 .4
12 .4
10
8 .1
8 .1
0 .2
0
Digitalised and scaled for CAN [12-bit]
1
1
0 .8
0 .62
0 .62
0 .5
0 .405 0 .405
0 .01
0
Threshold multiplied by maximum value
[m]
10
10
8
6 .2
6 .2
5
4 .05
4 .05
0 .1
0
Distance measurement of the device
multiplied by group 1 [m]
12 .34
9 .87
8 .76
7 .41
5 .28
4 .65
4 .23
3 .65
1 .59
0 .87
Binary result of the device at digital
output 1
0
1
0
0
1
1
0
1
0
0
In order to visualise a direct conversion of the physical switching outputs, the analogue speed
value is scaled to the range 0 . . .1 . This value can be mapped directly from the physical analogue
input to the 12-bit value of the CAN interface .
By moving the scaling into the logic, the programming of the controller becomes independent of
the device function .
15.3.4 "Extrinsic calibration" module
The "Extrinsic calibration" module provides the calibration settings of the device
The "Extrinsic calibration" module has the following settings:
Setting
Data type
Index
Description
Sensor angle
ROT X
Numerical
Single value (no index)
The angle of rotation of the device around the x-axis [rad] .
Sensor angle
ROT Y
Numerical
Single value (no index)
The angle of rotation of the device around the y-axis [rad] .
Sensor angle
ROT Z
Numerical
Single value (no index)
The angle of rotation of the device around the z-axis [rad] .
Sensor position X
Numerical
Single value (no index)
Distance of the device from the origin of the defined world
coordinates on the x-axis [m] .
Sensor position Y
Numerical
Single value (no index)
Distance of the device from the origin of the defined world
coordinates on the y-axis [m] .
Sensor position Z
Numerical
Single value (no index)
Distance of the device from the origin of the defined world
coordinates on the z-axis [m] .
15.3.5 "Diagnostic" module
The "Diagnostic" module provides information on the current status of the device .
The "Diagnostic" module has the following settings:
Setting
Data type
Index
Description
Available
Binary
Single value (no index)
The availability of CAN input values at the modules "Digital CAN input
signals" and "Analogue CAN input signals" is provided:
●
"0": CAN input values not available
●
"1": CAN input values available
Sensor
temperature
Numerical
Single value (no index) The current temperature of the device is provided [°C] .
Illumination
temperature
Numerical