IDS X  Series Training V2.3 | Contact ID Zone Reporting 

57 

 

Contact ID Zone Reporting  

This is the complete list of values that can be entered into locations 304 to 335 to extend the Contact ID reporting  
Value  CID  Description 

 

Value  CID  Description 

01 

100  Medical Zone 

 

3C 

303  RAM Checksum bad Zone 

02 

101  Personal Emergency Zone 

 

3D 

304  ROM checksum bad Zone 

03 

102  Fail to report in Zone 

 

3E 

305  System reset Zone 

04 

110  Fire Zone 

 

3F 

306  Panel programming changed Zone 

05 

111  Smoke Zone 

 

40 

307  Self- test failure Zone 

06 

112  Combustion Zone 

 

41 

308  System shutdown Zone 

07 

113  Water flow Zone 

 

42 

309  Battery test failure Zone 

08 

114  Heat Zone 

 

43 

310  Ground fault Zone 

09 

115  Pull Station Zone 

 

44 

311  Battery Missing/Dead Zone 

0A 

116  Duct Zone 

 

45 

312  Power Supply Overcurrent Zone 

0B 

117  Flame Zone 

 

46 

313  Engineer Reset User 

0C 

118  Near Alarm Zone 

 

47 

320  Sounder/Relay Zone 

0D 

120  Panic Zone 

 

48 

321  Bell 1 Zone 

0E 

121  Duress User 

 

49 

322  Bell 2 Zone 

0F 

122  Silent Zone 

 

4A 

323  Alarm relay Zone 

10 

123  Audible Zone 

 

4B 

324  Trouble relay Zone 

11 

124  Duress – Access granted Zone 

 

4C 

325  Reversing relay Zone 

12 

125  Duress – Egress granted Zone 

 

4D 

326  Notification Appliance Ckt. # 3 Zone 

13 

130  Burglary Zone 

 

4E 

327  Notification Appliance Ckt. #4 Zone 

14 

131  Perimeter Zone 

 

4F 

330  System Peripheral trouble Zone 

15 

132  Interior Zone 

 

50 

331  Polling loop open Zone 

16 

133  24 Hour (Safe) Zone 

 

51 

332  Polling loop short Zone 

17 

134  Entry/Exit Zone 

 

52 

333  Expansion module failure Zone 

18 

135  Day/night Zone 

 

53 

334  Repeater failure Zone 

19 

136  Outdoor Zone 

 

54 

335  Local printer out of paper Zone 

1A 

137  Tamper Zone 

 

55 

336  Local printer failure Zone 

1B 

138  Near alarm Zone 

 

56 

337  Exp. Module DC Loss Zone 

1C 

139  Intrusion Verifier Zone 

 

57 

338  Exp. Module Low Batt. Zone 

1D 

140  General Alarm Zone 

 

58 

339  Exp. Module Reset Zone 

1E 

141  Polling loop open Zone 

 

59 

341  Exp. Module Tamper Zone 

1F 

142  Polling loop short Zone 

 

5A 

342  Exp. Module AC Loss Zone 

20 

143  Expansion module failure Zone 

 

5B 

343  Exp. Module self-test fail Zone 

21 

144  Sensor tamper Zone 

 

5C 

344  RF Receiver Jam Detect Zone 

22 

145  Expansion module tamper Zone 

 

5D 

350  Communication trouble Zone 

23 

146  Silent Burglary Zone 

 

5E 

351  Telco 1 fault Zone 

24 

147  Sensor Supervision Failure Zone 

 

5F 

352  Telco 2 fault Zone 

25 

150  24 Hour Non-Burglary Zone 

 

60 

353  Long Range Radio Txmitter fault Zone 

26 

151  Gas detected Zone 

 

61 

354  Failure to communicate event Zone 

27 

152  Refrigeration Zone 

 

62 

355  Loss of Radio supervision Zone 

28 

153  Loss of heat Zone 

 

63 

356  Loss of central polling Zone 

29 

154  Water Leakage Zone 

 

64 

357  Long Range Radio VSWR problem Zone 

2A 

155  Foil Break Zone 

 

65 

370  Protection loop Zone 

2B 

156  Day Trouble Zone 

 

66 

371  Protection loop open Zone 

2C 

157  Low bottled gas level Zone 

 

67 

372  Protection loop short Zone 

2D 

158  High temp Zone 

 

68 

373  Fire trouble Zone 

2E 

159  Low temp Zone 

 

69 

374  Exit error alarm (zone) Zone 

2F 

161  Loss of air flow Zone 

 

6A 

375  Panic zone trouble Zone 

30 

162  Carbon Monoxide detected Zone 

 

6B 

376  Hold-up zone trouble Zone 

31 

163  Tank level Zone 

 

6C 

377  Swinger Trouble Zone 

32 

200  Fire Supervisory Zone 

 

6D 

378  Cross-zone Trouble Zone 

33 

201  Low water pressure Zone 

 

6E 

380  Sensor trouble Zone 

34 

202  Low CO2 Zone 

 

6F 

381  Loss of supervision - RF Zone 

35 

203  Gate valve sensor Zone 

 

70 

382  Loss of supervision - RPM Zone 

36 

204  Low water level Zone 

 

71 

383  Sensor tamper Zone 

37 

205  Pump activated Zone 

 

72 

384  RF low battery Zone 

Summary of Contents for X16

Page 1: ...Multi Language with Wireless Installer Training Firmware Version 2 3 X16 Stock Code 860 1 473 X16 X64 Stock Code 860 1 864 XS Training Manual...

Page 2: ...2 Contents IDS X Series Training V2 3...

Page 3: ...________________ 35 Wireless ______________________________________________________________________________________________ 38 Reporting Codes _________________________________________________________...

Page 4: ...wer supply 9 Programmable zone loop response 10 Up downloadable via software 11 Fax defeat to bypass fax answering machines 12 Optional tamper reporting per zone 13 Non volatile memory 14 Voice report...

Page 5: ...e alarm will power up automatically 2 Default button 3 Panel Status LED To default the panel physically remove power from the unit and press down the default button Replace power whilst still holding...

Page 6: ...more detailed information can be found at the end of the manual in appendix 1 Please note that devices especially between different manufacturers are different and the manuals should be thoroughly re...

Page 7: ...s the same as the onboard programmable outputs except that it triggers with 5V and not 12V The zone works exactly like a normal zone with an end of line resistor When using the zone it will replace th...

Page 8: ...e X Series first get both PIR heads to detect movement then press the tamper switch when in location 260 sub location 1 and the correct zone number has been selected Dip Sw Function Enable Disable Des...

Page 9: ...n selected Duevi Outdoor E Wall with PIR Microwave 866 DX EWF Note To learn the door contact to the X Series press the tamper switch when in location 260 sub location 1 and the correct zone number has...

Page 10: ...13 1000 14 2000 15 4000 16 8000 Hundreds Zone Value 9 100 10 200 11 400 12 800 Tens Zone Value 5 10 6 20 7 40 8 80 Zone Value 3 4 6 20 9 100 Total 124 Zone Value 1 1 4 8 Total 9 Enter Key The key has...

Page 11: ...nd zone 4 8 12 16 have a value of 8 H Hour m minutes s seconds Value 1 2 4 8 m m s s H H m m Example Programming Installer Mode Installer mode is where all program settings can be changed to suit any...

Page 12: ...ta value that needs to be in the location followed by the key 4 You can enter the next location or press the key to exit Installer mode Programming Extended Locations Sub location Method The sub locat...

Page 13: ...l come on if it was off or go off if it was on 5 On the LCD keypad when the key is pressed you will be taken to the option you have chosen This will show you the current value and if you want to then...

Page 14: ...wireless zones and settings Exercise Defaulting back to factory settings Location 1 to 8 Zone Type Location Type Extended Sub Location Can be programmed using the string method Loc Zone Types 1 Z1 Z2...

Page 15: ...of a Priority zone will cause the control panel to register a panic condition This zone type CANNOT be bypassed 04 INSTANT ZONE When the panel is armed the violation of an Instant zone will cause the...

Page 16: ...5 1 5 0 3 d Programming zones 7 and 8 using the sub location method Instructions Key presses Enter location 1 1 Enter the sub location number for zone 7 and press the key 7 Enter the value for an ext...

Page 17: ...mber of violations must happen in the time set If this does not happen the system will reset both Cross zone delay time is the time that the violations must take place within before a violation is tri...

Page 18: ...tamper monitoring This looks for a load on the siren port if the load goes missing then a tamper is triggered and logged If option 4 in location 571 is enabled a tamper will be sent to the monitoring...

Page 19: ...r some sort of trouble that causes the 12V output to fail 7 OFF Engineer s reset trouble display If this option is set in partition options location 211 to 218 and the alarm triggers this option will...

Page 20: ...ne Supervision This option enables or disables wireless supervision failures from triggering alarms Supervision monitors the wireless devices to make sure that they remain communicating with the syste...

Page 21: ...888888 Master User Code 1 1234 123456 User Codes 2 128 XXXX XXXX00 Valid Range 4 or 6 Default 4 Location 24 Account Code Number of Digits Location Type Standard The reporting account codes can be inc...

Page 22: ...ober 2 February 7 July 11 November 3 March 8 August 12 December 4 April Location 29 Day of the Week to End Daylight Savings Location Type Standard Select the day that daylight savings ends Value 1 2 3...

Page 23: ...ult Disable Location Type Standard The download code is a security code to stop any illegal connection and changing of data via external connections using IDSwift software If this option is enabled th...

Page 24: ...rmats their event reporting codes are automatically entered into reporting locations Locations 501 to 588 enable or disable reporting for Contact ID and SIA All other formats the reporting codes must...

Page 25: ...try the second number and go back to the first after it has succeeded with the second number Split reporting is when certain events are programmed to report to certain groups of phone numbers and each...

Page 26: ...he telephone number the serially connected device must dial to report any signals Note This option is only entered if the serial device has this option built in Location 61 to 68 Primary Account Codes...

Page 27: ...the user menu 6 ONOFF Zone Bypassable Enable or disable the zone from being bypassed 9 Profile 1 10 Profile 2 11 Profile 3 12 Profile 4 OFF Stay Profile This is to allocate the zone to a stay profile...

Page 28: ...ered here in the 24 hour format HHMM is when the system will start to monitor for no movement Format HHMM Default 0000 Valid range 0000 to 2359 Location 167 No movement auto arm stop time Location Typ...

Page 29: ...movement auto arm and no movement alarm days of the week LED ARM Days of the Week LED Alarm Days of the Week 1 Monday 9 Monday 2 Tuesday 10 Tuesday 3 Wednesday 11 Wednesday 4 Thursday 12 Thursday 5 F...

Page 30: ...must be set Location 190 Auto Delay Location Type Standard This location sets the delay period for the keypad buzzer warning before the panel auto arms At the completion of the Auto Arm Delay the pane...

Page 31: ...settings using the location method as an Installer would Note No settings can be changed that would compromise communication with the security company Panel functions that can be edited in maintenance...

Page 32: ...on 201 2 0 2 The green READY LED should be on the and ARM AWAY and POWER LEDs should be off This is a bitmapped location so data is entered by entering the zone number of the zone you want to allocate...

Page 33: ...zones 8 ON Zone Bypassing This enables or disables the ability for a user to bypass faulty zones using the 9 key 9 OFF Arm with Zones in the Entry Route Violated This allows movement to take place in...

Page 34: ...is armed and has communicated that to the security company successfully 7 OFF Stay zone reporting When enabled and stay closing is enabled all zones bypassed will be reported to the security company...

Page 35: ...d default all the keypad s LEDs will flash By pressing the key the keypad will ask the system for an ID The first available ID will be given to the keypad To clear the keypad ID hold down the 1 and 3...

Page 36: ...4 Exercise Instructions Key presses If not in installer mode enter into installer 9 9 9 9 To enable the keypad zone go to location 242 2 4 2 Again we are only changing keypad 3 so we will use the bitm...

Page 37: ...e keypad will switch all its LEDs off after the time programmed into location 22 Press any key to wake it up 3 OFF Global keypad status If this is enabled the keypad can view any partition on the syst...

Page 38: ...output 2 supervision loss 2 Default The second operation is a standalone default feature If all Dip switches are ON during power up then the unit will default Please power down after set appropriate...

Page 39: ...Armed LED ON Away LED flashing b Menu system now only awaiting sub location selection i User must enter number to advance into sub menu c When entering sub menus I e add wireless device or delete wir...

Page 40: ...ia keypad by a LONG OK beep as well as the Zone LED previously flashing will now be ON 3 The system will now wait for a new zone to be selected 4 key at any time will return the user back to the sub m...

Page 41: ...location 260 and scrolling to or entering option 2 the following will be displayed Scroll using Medical or Panic Keys Enter with key 1 Enter to enter the delete sub location to have the following disp...

Page 42: ...n entering location 260 and entering option 4 the following will be displayed 3 Hr Check in 12 Hr Check in Flashing 1 Enter the supervision time required by entering the correct option from the follow...

Page 43: ...is sent 4 Communication Restored When communication is restored the code is sent 5 Phone line tamper If the phone line is tampered with and the line voltage goes missing an alert is sent 6 Phone line...

Page 44: ...1 Wireless detector supervision failure Each device checks in with the controller at a predetermined time and if this signal is not received the alarm company is alerted that it has gone missing 2 Wir...

Page 45: ...he contact ID reporting code for each zone to extend what can be connected to each zone and what is reported to the control room Example If a gas detector is connect to zone 8 By entering 26 into loca...

Page 46: ...on Type Extended There is a sub location for each of the 8 partitions These reporting codes are sent when someone away arms the system using the quick arm key 1 Location 375 Quick Stay Reporting codes...

Page 47: ...n must also be entered so that the system knows what to do when triggered The action can be either a pulse or latch as discussed before Below are the values for the actions Value Output Action ACTION...

Page 48: ...on a zone and the tamper switch on the device is triggered 398 Zone Tamper Restoral Programmable Output When the tamper switch goes back to normal 399 Zone Shutdown Programmable Output If enabled and...

Page 49: ...ill only trigger when the system is armed but a 24 hour zone is always active therefore even if the system is unarmed and the zone is triggered the output will trigger Location 415 to 422 Zone trigger...

Page 50: ...send a signal either every 90min or 12 hours to confirm it is still available If the system does not receive the signals a supervision fail is logged 4 RF Detector Battery Low When the wireless devic...

Page 51: ...ocation Type Extended This location has 5 sub locations representing Ooutputs 1 to 5 on the main system board Installer Code 4 4 8 Output No h h m m Data format hhmm Valid Range 0000 2359 2400 disable...

Page 52: ...tion Default 1 ON Zone alarm reporting If this option is selected whenever a zone is violated the alarm reports via telephone 9 OFF 2 OFF Zone alarm restore When the zone restores the alarm reports vi...

Page 53: ...nal drops below 20 a message will be sent to alert the security company 15 OFF 8 ON AC Restored After AC is restored a message can be sent 16 OFF LED Default Action Explanation Split Reporting Option...

Page 54: ...ng Location Type Bitmap LED Default Action Explanation Split Reporting Option Default 1 OFF Bus device comms restored When a device has stopped communicating on the bus and when the fault is corrected...

Page 55: ...a fire zone and is violated a fire signal is sent to the security company 11 OFF 4 ON Medical Reporting When the M key or the option Medical alarm if no movement is detected is enable a medical signal...

Page 56: ...company 2 ON Stay Close Reporting Enable if a stay close signal is to me sent 3 ON Open Reporting Enable if a open signal is to me sent 4 OFF Siren Cancel Reporting Enable if the siren is active and a...

Page 57: ...6 Local printer failure Zone 1B 138 Near alarm Zone 56 337 Exp Module DC Loss Zone 1C 139 Intrusion Verifier Zone 57 338 Exp Module Low Batt Zone 1D 140 General Alarm Zone 58 339 Exp Module Reset Zone...

Page 58: ...Error user User C4 604 Fire test User 8F 458 User on Premises User C5 605 Status report to follow Zone 90 459 Recent Close User C6 606 Listen in to follow Zone 91 461 Wrong Code Entry Zone C7 607 Wal...

Page 59: ...OFF Off Bus wired peripheral tamper monitoring 11 OFF OFF Onboard dedicated panic silent 12 ON ON Low battery monitoring 13 ON ON Low battery cut out 14 OFF OFF Bypassing with user code 15 OFF OFF Ded...

Page 60: ...orting Locations 342 349 Close Reporting Codes Clears all codes Locations 350 357 Stay Close Reporting Clears all codes Locations 358 365 Open Reporting Clears all codes Locations 366 373 Siren Cancel...

Page 61: ...heral fail reporting 10 OFF Telephone module 1 3 OFF OFF Bus wired peripheral low battery reporting 11 OFF Telephone module 1 4 ON OFF Wireless Detector Battery Low 12 OFF Telephone module 1 5 OFF OFF...

Page 62: ...ON Test Report 16 OFF Telephone module 1 Location 575 Global Split Reporting 5 LED Factory Default Default 5 Action LED On Off Reporting Pair 1 OFF OFF IDSwift Download Accessed 9 OFF Telephone module...

Page 63: ...ON OFF Enable box tamper monitoring 9 ON OFF Enable siren monitoring 10 OFF OFF Disable bus wired peripheral tamper monitoring 11 OFF OFF Disable onboard dedicated panic audible 12 ON ON Enable low b...

Page 64: ...orting Locations 342 349 Close Reporting Codes Clears all codes Locations 350 357 Stay Close Reporting Clears all codes Locations 358 365 Open Reporting Clears all codes Locations 366 373 Siren Cancel...

Page 65: ...Telephone module 1 2 ON OFF Enable bus wired peripheral fail reporting 10 OFF Telephone module 1 3 OFF OFF Disable bus wired peripheral low battery reporting 11 OFF Telephone module 1 4 ON OFF Wirele...

Page 66: ...nic 15 OFF Telephone module 1 8 ON OFF Test Report 16 OFF Telephone module 1 Location 575 Global Split Reporting 5 LED Factory Default Default 6 Action LED On Off Reporting Pair 1 OFF OFF IDSwift Down...

Page 67: ...ry route violated 12 Entry beep 13 Exit beep Page 25 221 to 228 1 Automatic enabling of shutdown zones 2 Bypassing common zones 7 Stay zone reporting 8 Zone restoral signal sending option Page 26 241...

Page 68: ...57 Keypad output scheduling Page 41 572 1 Bus wired peripheral tamper reporting 2 Bus wired peripheral communication fail reporting Page 43 573 8 Bus wired peripheral tamper restore reporting Page 43...

Page 69: ...ireless device supervision time Page 30 302 to 303 Global split reporting options Page 35 304 to 335 Zone reporting Page 35 415 to 422 Zone triggered outputs Page 40 425 Wireless triggered outputs Pag...

Page 70: ...70 User Menu IDS X Series Training V2 3 Multi Language with Wireless User Menu Firmware Version 2 3 X16 Stock Code 860 1 473 X16 X64 Stock Code 860 1 864 XS Training Manual...

Page 71: ...confirm entry and save information 2 Hold until beep enter master user code and choose menu option 3 In dealing with options that have zone selections the LED keypad can only show 16 zones at a time T...

Page 72: ...exit zone 2 Enter a user code the exit delay will begin and exit via an entry exit zone Eg 2 3 3 2 NOTE If the entry exit zone is not triggered the system by default will automatically arm in the stay...

Page 73: ...by zone 3 etc 1 8 1 0 1 5 When complete press the key Toggling between the 2 stay profiles can be done in three ways 1 Toggle method Note only if there is more than one profile with stay zones a Pres...

Page 74: ...ess and hold the 2 chime zone key until the beep 2 Enter each zone to be a chime zone until complete for zones 1 to 16 4 6 1 1 To access zones 17 to 32 press the key Now zone 17 is represented by zone...

Page 75: ...te iv Teach remote transmitters to a user code Standard Master User Functions The master menu is for administering the system by adding deleting users adding remote transmitters etc To access the mast...

Page 76: ...seconds Enter the master code followed by the key 1 2 3 4 Enter the value to delete a user code followed by the key 2 Now enter the user code to be deleted followed by the key 5 8 7 9 When complete pr...

Page 77: ...to any partition Example Instruction Key presses Press and hold the key for 3 seconds Enter the master code followed by the key 1 2 3 4 Enter the value to delete a user code via a slot number followe...

Page 78: ...t 2 01 Onboard output 1 14 Zone expander 5 output 1 02 Onboard output 2 15 Zone expander 5 output 2 03 Onboard output 3 16 Zone expander 6 output 1 04 Onboard output 4 17 Zone expander 6 output 2 05 O...

Page 79: ...ay pulse time Option 26 Allows for the defaulting of the receiver Option 27 Allows for the identification of the receiver Option 28 Allows for the testing of the receiver Option 29 Allows for the view...

Page 80: ...add remotes using the advanced method followed by the key 2 1 Enter the remote receiver ID that the transmitter will be taught to followed by the key 1 Now enter the user code followed by the key 2 3...

Page 81: ...l rest in normally open 2 Panic When a panic is triggered via a button or the 3 second hold option the relay will trigger 3 Retrigger This stops the relay from retriggering for 20 seconds after an ini...

Page 82: ...ction Key presses Press and hold the key for 3 seconds Enter the master code followed by the key 1 2 3 4 Enter the value to default the remote receiver followed by the key 2 6 Enter the remote receive...

Page 83: ...rd Approx 3 seconds Options Summary of Programmable Options Option 40 Allows for the editing of the time Option 41 Allows for the editing of the date Instruction Key presses Press and hold the key for...

Page 84: ...r off via the keypad Mode 3 Output Alarm Memory Alarm memory holds information on zones that triggered tampered with and bypassed for the arm cycle that has just been disarmed Once the system arms aga...

Page 85: ...iolated Zone Violated New Partition Menu on LCD keypads When entering quick arm stay arm or stay go and the option is enabled all partitions will be shown with their status Menu status options i r rea...

Page 86: ...ion is triggered the alarm can only be armed again once the installer code has been entered 8 Box tamper The panel has pins to connect a switch that can monitor if the box is opened 9 Peripheral Devic...

Page 87: ...nt No Press RT Button Delete Remote Master Code 2 2 Receiver No User Code Button Properties Master Code 2 3 Receiver No Button No Properties Relay Properties Master Code 2 4 Receiver No Relay No Prope...

Reviews: