IDS X Series Training V2.3 | Hardware
7
7.3 Aux 12V
The X-
Series
Alarm Panel can supply 750mA of power to all bus-
wired peripherals, including keypads, expanders and remote
receivers, etc.
7.4 Siren
The siren connects directly to the siren output and can drive up to a 30 watt
siren.
Note: The siren must be self-driven and cannot be a speaker, etc.
7.5 Keypad Bus
The devices connected to the bus should be connected in a daisy
chain formation for the best results.
The keypad has a programmable output (PGM). The PGM functions
the same as the onboard programmable outputs, except that it
triggers with 5V and not 12V.
The zone works exactly like a normal zone with an end-of-line
resistor. When using the zone it will replace the zone that it has been
programmed as. E.g. if the keypad zone has been programmed as
zone 10, zone 10 on the board will be shut down and cannot be
used.
7. 6 Zones
No Tamper Tamper
Devices that are connected to zones are divided into two
categories, normally open (NO) or normally closed (NC).
Some devices have both and the installer can select either,
depending on their preference.
NOTE: The end of line resistor must be 3K3
Ω
(
Ω
= ohm)
For a tamper installation a 12k
Ω
and a 4K7
Ω
End of Line 3k3 Ohm 12K & a 4k7 Ohm resistor
resistor
X-
SERI
ES