34
Partition Options | IDS X Series Training V2.3
Locations 221 to 228: Extra partition options
Location Type: Bitmap
These are more partition options that can be set
LED
Default
Action
Description
1
OFF
Automatic Re-enabling of
Shutdown Zones at the Time of
the Dialler test
If a zone is disabled due to reaching the number of
triggers in location 10 when armed, the alarm will try and
re-enable those zones at auto test
2
OFF
Bypassing of Common Zones
If zones are in more than one partition and the zones may
need to be bypassed at some time this option must be
enabled in all partitions it belongs to
3
OFF
Delay Before Communications
This option will delay any communication for the time set
in location 45. Except for panic or duress signals
4
OFF
Keypad Lockout
If a person enters a wrong code the number of times set
in location 20 the keypad will stop responding to any key
presses, for the amount of time set in location 21
5
OFF
Disable Silent Keypad Panic
This will stop the siren from sounding if the P key on the
keypad is pressed and a panic is triggered
6
OFF
Toot on Successful
Communication
When closing reporting is enabled and this option is on
the siren will only toot once the system is armed and has
communicated that to the security company successfully.
7
OFF
Stay zone reporting
When enabled and stay closing is enabled all zones
bypassed will be reported to the security company
when
using 4x2 reporting
8
OFF
Zone restoral signal sending
option
When enabled a zone restoral will only be sent once the
siren time out period has completed
Location 230: Exit delay
Location Type: Extended
There is a sub-location for each of the 8 partitions.
This is the time the alarm waits before fully arming. During this time any zones that are entry/exit or follower
zones are disabled and only when the exit delay is finished do these zones become active. By default the
exit delay is indicated by the keypad beeping.
Format: mmss
Default: 0030
Valid range: 5959 to 5959
Exercise:
Location 231: Primary Entry delay
Location Type: Extended
There is a sub-location for each of the 8 partitions.
This is the time the alarm will allow a person from triggering the primary entry/exit zone to entering a valid
disarm code before sounding the alarm. When the entry/exit zone triggers, it automatically disables the
follower zones.
There is a secondary entry delay (location 232) for a different entry times.
Format: mmss
Default: 0030
Valid range: 5959 to 5959
Instructions
Keypad presses
Enter the location 230
[2][3][0] [*]
Enter partition 1‟s sub-location
[1] [*]
Change the 30 sec default to 10sec (mmss)
[0][0] [1][0] [*]
Exit the location
[#]