IDS X Series Training V2.3 | Wireless Device Hardware setup
9
Duevi Wireless Door Contact including input - 866-DX-PWF
Inputs 1 and 4 can be used but the serial number must be entered via keypad into location 260 sub-
location 1.
JP2 jumper: On = 12Hrs Off = 90min
Tamper On = Disabled Off = Enabled
Note: To learn the door contact to the X-
Series
press the tamper switch when in location 260 sub
location 1 and the correct zone number has been selected.
Duevi Wireless Indoor Wireless pet tolerant (18kg) PIR - 866-DX-PWF
SPV jumper: On =12Hrs Off = 90min
Note: To learn the indoor PIR to the X-Series press the tamper switch when in location 260 sub
location 1 and the correct zone number has been selected.
Duevi Outdoor E-Wall with PIR & Microwave - 866-DX-EWF
Note: To learn the door contact to the X-Series press the tamper switch when in location 260 sub-
location 1 and the correct zone number has been selected.
Dip Sw
Function
Enable /Disable
Description
1
Mode
Off = Test Mode
On = Normal
2
Pulse
Off = 1 pulse
On = 2 pulse
3
Tamper
Off = Enabled
On = Disabled
4
LED
Off = No LED
On = LED
Dip Sw
Function
Enable /Disable
Description
1
Tamper
Off = Enabled
On = Disabled
2
Sensitivity
Off = High
Door installation
On = Low
Window installation
3
Transmission
Off = Normal
In test mode the device will transmit
every time it is triggered
On = Test
4
Supervision
Off = 90 minutes
This is the interval that the device waits
between supervision signals that are
sent to the X-Series alarm
On = 12 hours
1 2 3 4
Input 1
Serial No: + 2
Input 2
Common
Input 3
Parallel to
reed switch
Serial No:
Input 4
Serial No: + 1