IDS X Series Training V2.3 | Scheduled Output triggers
51
Location 429 to 434: Zone Expander Outputs Pulse Length
Location Type: Extended
Each of the six zone expanders has two outputs.
[Installer Code] [*] [location] [*] [Output No.] [*] [m] [m] [s] [s] [*]
Data format: mmss
Valid Range: 0000 – 5959
Default: 0002
Location 437: Keypad Outputs Pulse Length
Location Type: Extended
Each of the eight keypads has an output.
[Installer Code] [*] [4] [3] [7] [*] [Output No.] [*] [m] [m] [s] [s] [*]
Data format: mmss
Valid Range: 0000 – 5959
Default: 0002
Scheduled Output triggers
An output can be scheduled to turn on or off by time and day
Location 448: Onboard Output Scheduling
Location Type: Extended
This location has 5 sub-locations representing Oo
utputs 1 to 5 on the main system board
.
[Installer Code] [*] [4] [4] [8] [*] [Output No.] [*] [h] [h] [m] [m] [*]
Data format: hhmm
Valid Range: 0000 – 2359 (2400 disables)
Default: 2400
Location 449 to 454: Zone Expander Output Scheduling
Location Type: Extended
This location has 2 sub-locations representing Each the 2 outputs on each expander.zone expander has
two outputs.
[Installer Code] [*] [location [Output No.] [*] [h] [h] [m] [m] [*]
Data format: hhmm
Valid Range: 0000 – 2359 (2400 disables)
Default: 2400
Location 457: Keypad Output Scheduling
Location Type: Extended
This location has 8 sub-locations representing Each keypad has an output that can be triggeredthe output
on each keypad.
[Installer Code] [*] [4] [5] [7] [*] [Output No.] [*] [h] [h] [m] [m] [*]
Data format: hhmm
Valid Range: 0000 – 2359 (2400 disables)
Default: 2400