72
Standard User Functions | IDS X Series Training V2.3
Standard User Functions
The following are the functions that all users can use.
Away Arm
When the system is armed in away mode, all zones are active and ready to trigger if an intrusion is
detected.
The following zone types work a little different when the system is armed.
1.
Entry / exit.
a.
When arming, it is only armed once the system has completed the exit time out, giving
everyone time to exit the building.
b.
When armed, and the zone is triggered, the system begins the entry countdown giving you
time to disarm
2.
Follower.
a.
This zone is never active during the arming or disarming time.
b.
If the entry / exit zones are not triggered then this zone is active.
How to away arm the system
1.
Press and hold the [1] key until the exit delay starts, and then leave the premises via the entry / exit
zone.
2.
Enter a user code, the exit delay will begin, and exit via an entry / exit zone. (Eg. [2][3][3][2])
NOTE:
If the entry / exit zone is not triggered, the system by default will automatically arm in the
stay mode. (This can be changed in the installer mode.)
3.
Use a remote transmitter.
Stay Arm
This option is when someone is inside the premises and the system must be armed, but certain zones
must not trigger when someone enters that area. Stay arm, when setup, will automatically turn off (bypass)
those areas that will have movement once armed.
How to stay arm:
1.
Press and hold the [5] key until the system arms
2.
Enter a user code and do not exit
How to create stay zones
A stay zone is a zone that will automatically be bypassed when the system arms in the stay mode.
Explanation
Key Presses
Press and hold the [3] stay key until the beep
[3]
Stay
Enter each zone to be bypassed until complete, then press the [#]
key to exit
[5][*][1][7][*][1][8][*][2][1][*].....[#]
There are 4 stay profiles so that different zones can be bypassed depending on different scenarios that
may arise.