IDS X Series Training V2.3 | Event Reporting Codes
55
Location 575 Global Split Reporting
Location Type: Bitmap
LED On/Off Action
Explanation
Split
Reporting
Option
Default
1
OFF
IDSwift Download
Accessed
This option reports when the system has been
communicated with by the download software
9
OFF
Location 581 - 588 Partition Split Reporting
Location Type: Bitmap
LED On/Off Action
Explanation
Split
Reporting
Option
Default
1
ON
Duress reporting
When a user code is made into a
duress code and is used this
enables the contact ID code to be
sent to the security company
9
OFF
2
ON
Keypad Panic Reporting
When the “P” key on the keypad is
pressed a panic signal is sent to the
security company
10
OFF
3
ON
Fire reporting
When the “F” key is pressed or a
zone is a fire zone and is violated a
fire signal is sent to the security
company
11
OFF
4
ON
Medical Reporting
When the “M” key or the option
“Medical alarm if no movement is
detected” is enable a medical signal
will be sent if this option is enabled
12
OFF
5
ON
Keypad Lockout Reporting
If this option is enabled in location
221 – 228 and an incorrect code is
entered the number of times set in
location 20 within the time set in
location 21, the signal will be sent
13
OFF
6
Reserved
7
Off
Arm without user code
Reporting
When arming with the “Quick Arm”
keys or a arm/disarm zone this
option must be enabled to send an
arm signal
15
OFF
8
Reserved
Location 600 - 616 Voice Module Reporting
Location Type: Standard
The voice module, if installed, will report programmed events to the telephone numbers entered into these
locations. Depending on the location the telephone number is entered into will depend on the partition the
person can interact with via the voice module.