background image

 

 
Ex

Cam

 IP13xx 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

User manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for ExCam IP1354

Page 1: ...ExCam IP13xx User manual ...

Page 2: ...Safety guidelines 16 4 Illustration of the model key 16 5 Commissioning 18 5 1 Step 1 Installation 18 5 2 Step 2 Electrical connection 18 5 2 1 Potential equalization 19 5 2 2 Connection and protection 20 5 2 3 Tests prior to switching on voltage 24 5 3 Testing of the status LED 25 5 4 Step 3 Adjusting the lens 26 5 4 1 Work preparation 27 5 4 2 Opening the pressure resistant housing 27 5 4 3 Adju...

Page 3: ...02 T and plug contact RJ45 23 Figure 5 6 RJ45 Contact assignment 23 Figure 5 7 SKD01 Pin assignment 23 Tab 5 3 Pin assignment supply cable 24 Table 5 4 Status and control LED 25 Table 5 5 Lens data 26 Figure 5 8 Removing the protection roof 1 2 28 Figure 5 9 Removing the protection roof 2 2 28 Figure 5 10 Opening the ExCam IPxxx 29 Abb 5 11 Mounting adapter with installation components 30 Figure 5...

Page 4: ...e ExCam IP1354 user manual into ExCam IP135x Series Reviewed and approved October xx 2014 S Seibert 1 December 05 2014 S Seibert Revision and approval Reviewed and approved December 05 2014 S Seibert 2 April 13 2016 T Gruber Various revisions Extension of the IP13xx Series with Axis products P1364 and P1365 discontinuation of P1355 Renaming of the document from IP135x Series to IP13xx Series Updat...

Page 5: ...nd the dust group IIIC conductive dusts and flammable fibrous ma terial as well as in mining Besides the stationary use the explosion proof cameras of theT08 ExCam Series are certified to be also used for mobile applications hand held etc The Ex d stainless steel housing allows additional alloys a powder coating or coats of varnishes in different RAL colors as well as various mechanical accessorie...

Page 6: ...68 Explosion protection mining Ex d I Mb Protection level IP 68 IEC EN 60529 Transportation storage temp EX 0 C 50 C Ambient temperature EX 1 60 C 65 C T6 60 C 70 C T5 Nominated body TÜV Rheinland number 0035 EC Type Examination TÜV 14 ATEX 7539 X_1st supplement IECEx TUR 14 0026X_issue No 1 Additional certificates EAC Ex TC_RU_C_DE MIO62 B 01921 Test protocol ATEX 557 Ex 539 00 14 Test report IEC...

Page 7: ...power 48 V DC 44 54 V DC Maximum power input 7 9 W 2 2 3 Axis P1364 Power supply PoE IEEE 802 3af 802 3at Type 1 class 3 Reference power 48 V DC 44 54 V DC Maximum power input 7 9 W 4 3 W typical 2 2 4 Axis P1365 Power supply PoE IEEE 802 3af 802 3at Type 1 class 3 Reference power 48 V DC 44 54 V DC Maximum power input 7 9 W 3 6 W typical 2 2 5 Axis P1365 MkII Power supply PoE IEEE 802 3af 802 3at...

Page 8: ...issipation via housing Per module the switch on power can reach Pmax 100W Supply cable fine wire fuses have to be dimensioned accordingly by the end user A super slow TT trigger charac teristic is recommended The typical continuous power rating at the low temperature range TAMB 30 C is P 30 C 12 2 W at a saturated condition The typical continuous power rating at the artic temperature range TAMB 60...

Page 9: ...R Stahl GmbH Outer diameter 9 1 0 2mm Wall thickness 1 0 0 1mm Bending radius 10 x outer diameter at installation 5 x outer diameter after installation Tensile Max 140N Temperature range 10 C to 50 C at point of installation 60 C to 80 C fixed installed Conductor design 4 x 2 x AWG22 1 blank CAT 6a Isolation SFS PE foamed Core diameter 1 52 0 02 mm Color code IEC 708 1 Pair shielding Compound alum...

Page 10: ...egrated pressure barrier with elastomer sealing on the outer sheath e g ADE 4F MsNi Type5 M20x1 5 CAPRI with additional strain relief At a connection cable length of 3m with integrated pressure barrier epoxide compound grouting of the single conductors and duroplast elastomer sealing of the outer sheath e g 8163 2 PXSS2K M20x1 5 R Stahl GmbH Outer diameter 7 5 mm Outer sheath Polyurethane mixture ...

Page 11: ...h according to DIN EN 50334 VDE 0293 334 Classification ETIM 5 0 Class ID EC 000104 ETIM 5 0 type Control cable Conductor insulation Thermal Plastic Elastomer TPE Nominal current U0 U 300 500 V AC DC Test voltage 3000 V Temperature range 40 C to 90 C occasional movement 50 C to 90 C fixed installation User interface P Plug version n a upon request K terminal block version 3x 1 5 mm2 3G1 5 Cu stran...

Page 12: ...n 1506 pdf 2 6 3 Axis P1364 Data sheet http www axis com files datasheet ds_p1364_1511096_en_1512 pdf User manual http www axis com files manuals um_p1364_1510439_en_1601 pdf 2 6 4 Axis P1365 Data sheet http www axis com files datasheet ds_p1365_60562_en_1503_hi pdf User manual http www axis com files sales um_p1365_1489706_en_1507 pdf 2 6 5 Axis P1365 MkII Data sheet http www axis com files datas...

Page 13: ...ptional MNo 1 4301 X5CrNi18 10 AISI 304 V2A MNo 1 4305 X8CrNiS18 9 AISI 303 MNo 1 4401 X5CrNiMo17 12 2 AISI 316 V4A MNo 1 4571 X6CrNiMoTi17 12 2 AISI 316Ti V4A 6 Functional temperature range concerning the operational temperature range of the installed components according to manufacture declarations MTBF meantime ration duration between failures For ambient temperature ranges relevant for explosi...

Page 14: ...m universal adapter EN AW ALSi1MgMn PTC ceramics PUR and additional thermoplastic plastics optical and electronical components etc Attention The Axis module is equipped with an ML614R battery which supplies the real time clock RTC These lithium button cells 3 0 V dispose of 1 2 dimethoxymethane ethylengly coldimethylether EGDME CAS No 110 71 4 8 The protective coating of the housing underlies the ...

Page 15: ...length 12 5mm acc to DIN EN 60079 1 largest gap length 0 15mm DIN EN 60079 1 Average surface finish Ra 2 0 µm DIN ISO 468 Ra 6 3 µm acc to DIN EN 60079 1 2008 5 2 2 Cable glands 2 x M20 1 5_12 mm ISO metrical fine thread acc to DIN13 2 quality 6H medium or fine acc to ISO 965 1 ISO 965 3 support ing gripping threads 5 acc to requirements of DIN EN 60079 1 2008 5 3 table 2 Cylindrical gaps Media re...

Page 16: ...tion of the ExCam IP13xx Series 2 T08 Production type concerning the certifications of the T08 ExCam Series EC type examination TÜV 14 ATEX 7539 X_1st supplement IECEx TUR 14 0026X_1st supplement and EAC Ex TC RU C DE MIO62 B 01921 3 VA2 2 K1 BOR T07 Ex d housing with large diameter ØVA 113 mm and large sight glass QBOR 72 mm effective translucent area 4 VA2 2 K1 BOR T07 housing with maximum body ...

Page 17: ...tion standard SKD02 T CAT6a 8x single conductor AWG22 1 twisted pair solid conductor copper blank 0 33 mm 2 Ø 0 64 mm approx 6 mm striped 1x shield CU braid tinned 1 5 mm 2 with ferules blue Ölflex 440P Supply 3G1 5mm 2 Cu Sheath about 12 cm stripped and furnished with bend relief shrink tubing P Plug termination optional SKD02 T CAT6a RJ 45 network plug heavy duty AWG 26 22 e g Type Weidmüller IE...

Page 18: ...location Mounting options and conditions accessories as well as safety guidelines are described in the EX installation manual of the T08 ExCam Series 5 2 Step 2 Electrical connection Attention The electrical connection of the equipment must be executed by quali fied personnel only Attention It is mandatory that the housing of the ExCam Series has to be grounded via a PE connection Attention The mi...

Page 19: ...by the user is prohibited Depending on the model option the ending of the camera s ca ble connection is either stripped to the blank Cu conductors or furnished with a plug 5 2 1 Potential equalization Figure 5 1 ExCam IP13xx potential equalization The potential equalization earthing of the camera housing is mandatory in order to avoid electrostatic charging and hence spark generation The screw ter...

Page 20: ... and supply cable Figure 5 3 ExCam IP13xx T08 VA2 2 K1 BOR C XXX K N Cable gland 1 SKD02 T digital video stream control and power supply PoE of the camera module Cable gland 2 optional Ölflex 440P Power supply for CB06 circuit board PTC heating elements and further devices if applicable via a relays control build to order ...

Page 21: ...ly PoE of the camera is carried out In order to guarantee the power supply Power Device PD of the ExCam IP13xx Series a Power over Ethernet component Power Sourcing Equipment PSE has to be available at the connecting side e g a PoE Switch a PoE Injector or Midspan which meets the specification IEEE 802 3af or 802 3at Type 1 Class 3 classification power 26 30 mA 48 VDC max feed power PSE 15 4 W max...

Page 22: ...contact 4 5 is the positive pole and 7 8 is the negative pole The T08 ExCam Series supports both modes and the used power source PSE determines the mode During operation and interaction with a visualization video management software or dur ing web interface access it is allowed disconnecting the ExCam IP13xx Series from and later reconnecting it to the network hot plugging The same is valid for a ...

Page 23: ...nned copper wires Ø 0 13 mm AWG 36 shield single twisted pair pins n a n a 10 n a Aluminum syn thetic strapp twisted Table 5 2 Pin assignment SKD02 T and plug contact RJ45 Figure 5 6 RJ45 Contact assignment Particularly in EMC critical environments it is important to earth the shield at the terminal block side q v figure 5 3 pin with black shrink tubing and blue ferule Figure 5 7 SKD01 Pin assignm...

Page 24: ...tandardly the supply is car ried out via the supply cable Ölflex 440P cable gland 2 q v figure 5 2 and 5 5 Con nection assignment and supply protection according to table 5 3 Potential Pin no Color Ölflex 440P IEC60757 Cond design Voltage Maximum power in put protection type L Maximum power in put protection type LL L 1 BK 1 5 mm 2 litz wire 24 VDC 20 W fuse L 2000 mA T time lag PTC inrush high in...

Page 25: ...nt green light is visible Note It is possible to configure the status LED in such a manner that in normal operation it is not illuminated or only blinks when the camera is accessed Yellow It is illuminated permanently when the camera is turned on as well as when the camera is set back to default settings Red In case of an activation failure the light blinks slowly Usage of the fo cus assistant Col...

Page 26: ...depth of field and quickly changing light conditions also manually adjustable via web interface Precesion automatic Motor control included in lens for a large depth of field and quickly changing light conditions also manually adjustable via web interface Precesion automatic Motor control included in lens for a large depth of field and quickly changing light conditions also manually adjustable via ...

Page 27: ...talkie to the control room Use appropriate tools Make sure you have a secure foothold Avoid static charge 5 4 2 Opening the pressure resistant housing In case it is necessary to adjust the picture the pressure resistant housing has to be opened and after completion of the work securely tightened again Please be very care ful and follow thoroughly the steps of this manual WARNING DO NOT OPEN IN HAZ...

Page 28: ... gon socket screws DIN 912 ISO 4762 located at the cable gland flange of the stainless steel housing including the washer springs DIN 127 A q v figure 5 10 Avoid skin or clothing contact with the screw threads as they dispose of LOCTITE 243 chemical basis Dimethacrylatester It is used to protect the screws from loosening due to shocks vibrations but it is also used for sealing purposes It is not a...

Page 29: ...B06 temperature controller and if applicable auxiliary relays and terminal blocks are fixed to the cable gland flange Beware also of tilting and work very carefully to avoid damaging the components Avoid skin and clothing contact with the cylindrical fit the surface is treated with lubrication paste oleaginous to protect the surface against frictional corrosion and mechanical strain When opening t...

Page 30: ...ivated greyed out the aperture is already open 3 Now click on the Reset button in order to reset the focal lens to default value 4 Loosen the zoom as well as sharpness control at the lens by turning counter clockwise Move both controllers and adjust the zoom as well as the sharpness as required Check the picture quality in the window below 5 Tighten the zoom as well as sharpness control again 6 Wi...

Page 31: ...he web interface they are also available in a download list or as an ftp file to the network The videos saved on the storage card can be accessed also via the FTP server within the network If the SD card has to be changed the new storage card should be blank and pre formatted with an ext4 or vFAT data system The SD card slot is located on the bottom side behind the camera module q v figure 5 13 Fi...

Page 32: ... green the camera mod ule Axis P13xx has been reset to Axis default settings This may take up to one minute If no DHCP Server is available within the network the IP address is 192 168 0 90 subnet masking 255 255 255 0 5 Now IP address and password can be re assigned If the hardware reset was not successful or if the cameras still does not work properly anymore faulty browser visualization picture ...

Page 33: ...g Mo lykote P 40 paste for standard applications or special lubrication agents such as OKS 403 for seawater environments The screw connections of the flange and housing have to be tightened in crosswise se quence with a torque of 3 Nm Please avoid extensive tightening this might lead to a torn screw etc affecting improperly the enclosure s pressure resistance Ex If the camera does not provide the ...

Page 34: ...ommended browsers are Internet Explorer with MS Windows Sa fari with Macintosh and Firefox with Windows and additional operating systems To carry out video streaming via the Microsoft Internet Explorer installing the AXIS Media Control AMC is required The installation request is executed during the initial commissioning In order to visualize the H 264 video streams QuickTimeTM is recom mended For ...

Page 35: ...tex download treiber software In case it is not possible to assign the IP address it might be necessary to change the firewall settings The AXIS IP Utility tool automatically recognizes all ExCam devices and displays them It can also be used to manually assign a static IP address Please note that the ExCam IP13xx network camera has to be installed within the same network segment physical subnet as...

Page 36: ...ng the password please fol low the below steps 1 Click on the button Create self signed certificate 2 Enter the desired information and click OK The certificate is issued and the password can be entered Please note that the entire data transfer of the ExCam IP13xx will be encrypted 3 Enter the desired password and repeat it in order to ensure correct spelling Click on OK to configure that password...

Page 37: ...maintenance measures are necessary they have to be initiated and or executed 8 Repairs and Maintenance Repairs must only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged pressure resistant housings have to be replaced completely If in doubt return the applicable part to SAMCON Prozessleittechnik GmbH Repairs concerning the explosion protection must only be carried out b...

Page 38: ...ras and integrated pressure barrier within the cable gland compound grouting of the single conductors The design shows the maximum dimen sions For cable glands with elastomer sealing of the outer sheath the dimensions in the depth is reduced by 30 mm T08 VA2 2 K1 BOR C XXX X L L Figure 10 1 Dimensions of the T08 ExCam IP13xx with K1 flange ...

Page 39: ...Doc ID 141021 PT08BA TG ExCam IP13xx Series_en_rev 03 page 39 of 44 T08 VA2 2 K2 BOR C XXX X N Figure 10 2 Dimensions of the T08 ExCam IP13xx with K2 flange ...

Page 40: ...Doc ID 141021 PT08BA TG ExCam IP13xx Series_en_rev 03 page 40 of 44 T08 VA2 2 K1 BOR C XXX X L L with accessories Figure 10 3 Dimensions of the T08 ExCam IP13xx with accessories ...

Page 41: ...Doc ID 141021 PT08BA TG ExCam IP13xx Series_en_rev 03 page 41 of 44 11 Notes ...

Page 42: ...Doc ID 141021 PT08BA TG ExCam IP13xx Series_en_rev 03 page 42 of 44 ...

Page 43: ...Doc ID 141021 PT08BA TG ExCam IP13xx Series_en_rev 03 page 43 of 44 ...

Page 44: ...Doc ID 141021 PT08BA TG ExCam IP13xx Series_en_rev 03 page 44 of 44 Schillerstrasse 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31 ...