62
Default 6 | IDS X Series Training V2.3
Location 574 Global Split Reporting 4
LED Factory
Default
Default 5
Action
LED
On/
Off
Reporting Pair
1
OFF
OFF
Bus device comms restored
9
OFF Telephone module 1
2
OFF
OFF
Bus device battery restored
10
OFF Telephone module 1
3
OFF
OFF
Wireless detector battery restored
11
OFF Telephone module 1
4
OFF
OFF
Wireless detector supervision
restored
12
OFF Telephone module 1
5
OFF
OFF
Wireless receiver jam restored
13
OFF Telephone module 1
6
OFF
OFF
Wireless detector RSSI low
restored
14
OFF Telephone module 1
7
ON
ON
Dedicated Panic
15
OFF Telephone module 1
8
ON
ON
Test Report
16
OFF Telephone module 1
Location 575 Global Split Reporting 5
LED Factory
Default
Default
5
Action
LED
On/Off
Reporting Pair
1
OFF
OFF
IDSwift Download Accessed
9
OFF
Telephone module 1
Location 581 - 588 Partition Split Reporting
LED Factory
Default
Default
5
Action
LED
On/Off
Reporting Pair
1
ON
ON
Enable duress reporting
9
OFF
Telephone module 1
2
ON
ON
Enable keypad panic reporting
10
OFF
Telephone module 1
3
ON
ON
Enable fire reporting
11
OFF
Telephone module 1
4
ON
ON
Enable medical reporting
12
OFF
Telephone module 1
5
ON
ON
Enable keypad lockout reporting
13
OFF
Telephone module 1
6
OFF
Reserved
14
Reserved
7
OFF
OFF
Disable armed without user code
reporting
15
OFF
Telephone module 1
8
OFF
Reserved
16
Reserved
Location 600 – 616 Voice Module Phone Numbers
All numbers cleared