IDS X Series Training V2.3 | Default 5
59
Default 5
Location 14 Global Options
LED
Factory
Default
Default
5
Action
1
ON
ON
A user assigned to any partition may cancel the siren
2
OFF
OFF
Keypad trouble beep
3
OFF
OFF
Telephone line monitoring
4
OFF
OFF
Keypad beep on successful reporting to the base station
5
ON
ON
Keypad Fire, Medical and Panic keys
6
ON
ON
Display of bypassed and stay zones when armed
7
OFF
OFF
Siren delay
8
ON
OFF
Box tamper monitoring
9
ON
OFF
Siren monitoring
10
OFF
Off
Bus-wired peripheral tamper monitoring*
11
OFF
OFF
Onboard dedicated panic – silent
12
ON
ON
Low battery monitoring**
13
ON
ON
Low battery cut-out**
14
OFF
OFF
Bypassing with user code***
15
OFF
OFF
Dedicated Panic Zone Bypassing
16
OFF
OFF
Remote transmitters are able to cancel a panic condition
Location 41 - 44 Communication Format
Factory
Default
Default
5
Format Name
Description
5
5
Contact ID
Dual Tone HS, DTMF
Location 46 Reporting Option
LED Factory
Default
Default 5
Action
1
ON
ON
Enable Tone Dialling
2
OFF
OFF
Keep Two Separate Telephone Numbers
3
OFF
OFF
Disable Dual Reporting
4
OFF
OFF
Disable Alternate Reporting
Locations 51 – 54 Primary Telephone Numbers
Clears all numbers