Introduction
This chapter provides a list of FC6A Series MicroSmart instructions and describes their functions.
The instructions are divided into basic instructions, which perform sequencing, and advanced instructions, which perform moves,
comparisons, Boolean computations, binary arithmetic operations, bit shifts, and other operations.
Basic Instruction List
Symbol
Name
Function
See Page
(LAD Programming
Manual)
AND
And
Series connection of NO contact
4-4
AND LOD
And Load
Series connection of circuit blocks
4-5
ANDN
And Not
Series connection of NC contact
4-4
BPP
Bit Pop
Restores the result of bit logical operation which was saved
temporarily
4-6
BPS
Bit Push
Saves the result of bit logical operation temporarily
4-6
BRD
Bit Read
Reads the result of bit logical operation which was saved
temporarily
4-6
CC=
Counter Comparison (=)
Equal to comparison of counter current value
4-18
CC>=
Counter Comparison (>=)
Greater than or equal to comparison of counter current value
4-18
CDP
Dual Pulse Reversible Counter
Dual pulse reversible counter (0 to 65,535)
4-11
CDPD
Double-Word Dual Pulse
Reversible Counter
Double-word dual pulse reversible counter (0 to 4,294,967,295)
4-14
CNT
Adding Counter
Adding counter (0 to 65,535)
4-11
CNTD
Double-Word Adding Counter
Double-word adding counter (0 to 4,294,967,295)
4-14
CUD
Up/Down Selection
Reversible Counter
Up/down selection reversible counter (0 to 65,535)
4-11
CUDD
Double-Word Up/Down
Selection Reversible Counter
Double-word up/down selection reversible counter
(0 to 4,294,967,295)
4-14
DC=
Data Register Comparison (=)
Equal to comparison of data register value
4-20
DC>=
Data Register Comparison (>=)
Greater than or equal to comparison of data register value
4-20
END
End
Ends a program
4-30
JEND
Jump End
Ends a jump instruction
4-29
JMP
Jump
Jumps a designated program area
4-29
LOD
Load
Stores intermediate results and reads contact status
4-1
LODN
Load Not
Stores intermediate results and reads inverted contact status
4-1
MCR
Master Control Reset
Ends a master control
4-27
MCS
Master Control Set
Starts a master control
4-27
OR
Or
Parallel connection of NO contact
4-4
OR LOD
Or Load
Parallel connection of circuit blocks
4-5
ORN
Or Not
Parallel connection of NC contact
4-4
OUT
Output
Outputs the result of bit logical operation
4-1
OUTN
Output Not
Outputs the inverted result of bit logical operation
4-1
RST
Reset
Resets output, internal relay, or shift register bit
4-3
SET
Set
Sets output, internal relay, or shift register bit
4-3
SFR
Shift Register
Forward shift register
4-22
SFRN
Shift Register Not
Reverse shift register
4-22
SOTD
Single Output Down
Falling-edge differentiation output
4-26
Summary of Contents for FC6A series
Page 1: ...B 1722 2 FC6A SERIES All in One Type User s Manual ...
Page 10: ...TABLE OF CONTENTS Preface 9 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 28: ...1 GENERAL INFORMATION 1 18 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 286: ...6 DEVICES 6 32 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 334: ...7 HMI FUNCTION 7 48 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 340: ...8 INSTRUCTIONS REFERENCE 8 6 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 360: ...9 FUNCTIONAL MODULES 9 20 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...
Page 368: ...10 ANALOG CARTRIDGE 10 8 FC6A SERIES MICROSMART ALL IN ONE TYPE USER S MANUAL FC9Y B1722 ...