14-5
D
D
Command table (continued)
14
CONTROL COMMAND
Command
Sub command
Description
1A
050035
Send/read the band selection for
operating frequency band signal
output to ACC-A. (0=MAIN,
1=SUB, 2=TX)
050036
Send/read the band selection for
operating frequency band signal
output to ACC-A. (0=MAIN,
1=SUB, 2=TX)
050037
Send/read relay type selection
(0=Lead, 1=MOS-FET)
050038
Send/read main band’s external
meter output selection (0=Auto,
1=S (main), 2=Po, 3=SWR,
4=ALC, 5=COMP, 6=V
D
, 7=I
D
)
050039
Send/read sub band’s external
meter output selection (0=Auto,
1=S (sub), 2=Po, 3=SWR,
4=ALC, 5=COMP, 6=V
D
, 7=I
D
)
050040
Send/read main band’s external
meter output level
(0=0% to 255=100%)
050041
Send/read sub band’s external
meter output level
(0=0% to 255=100%)
050042
Send/read reference signal in/out
setting (0=OFF, 1=IN, 2=OUT)
050043
Send/read reference signal fre-
quency setting
(0=0% to 255=100%)
050044
Send/read LCD unit backlight
brightness (0=0% to 255=100%)
050045
Send/read switch indicator bright-
ness (0=0% to 255=100%)
050046
Send/read screen image type
(0=A, 1=B, 2=C)
050047
Send/read frequency readout font
(0=Italic (1), 1=Italic (2), 2=Italic (3),
3=Italic (4), 4=Round (1),
5=Round (2), 6=Round (3),
7=Shadow (1), 8=Shadow (2),
9=Shadow (3), 10=Qubic (1),
11=Qubic (2), 12=Qubic (3),
13=Qubic (4), 14=IC-780 (1),
15=IC-780 (2), 16=IC-780 (3),
17=IC-780 (4))
050048
Send/read font for other than fre-
quency readout
(0=Normal, 1=Slim)
050049
Send/read meter type
(0=Standard, 1=Edgewise, 2=Bar)
050050
Send/read meter type during wide
screen or mini scope indication
(0=Edgewise, 1=Bar)
050051
Send/read peak hold set
(0=OFF, 1=ON)
050052
Send/read memory name indica-
tion setting (0=OFF, 1=ON)
050053
Send/read audio peak filter width
pop-up indication setting
(0=OFF, 1=ON)
050054
Send/read manual notch width
pop-up indication setting
(0=OFF, 1=ON)
050055
Send/read output signal setting for
external display (0=OFF, 1=ON)
050056
Send/read synchronous pulse
level setting (0=L, 1=H)
Command
Sub command
Description
1A
050057
Send/read opening message indi-
cation (0=OFF, 1=ON)
050058
Send/read opening message con-
tents (see p. 14-9 for details)
050059
Send/read date (20000101=1st
Jan. 2001 to 20991231=31st Dec.
2099)
050060
Send/read time (0000=00:00 to
2359=23:59)
050061
Send/read clock 2 function
(0=OFF, 1=ON)
050062
Send/read offset time for clock 2
(240001=–24:00 to 24:00)
050063
Send/read clock 2 name (up to 3-
character; see p. 14-9)
050064
Send/read calibration marker
(0=OFF, 1=ON)
050065
Send/read confirmation beep
(0=OFF, 1=ON)
050066
Send/read band edge beep
(0=OFF, 1=ON)
050067
Send/read main band’s beep
audio frequency
(50=500 Hz to 200=2000 Hz)
050068
Send/read sub band’s beep audio
frequency
(50=500 Hz to 200=2000 Hz)
050069
Send/read quick dualwatch func-
tion (0=OFF, 1=ON)
050070
Send/read quick split set (0=OFF,
1=ON)
050071
Send/read FM split offset –9.999
to +9.999 MHz for HF
(see p. 14-10 for details)
050072
Send/read FM split offset –9.999
to +9.999 MHz for 50 MHz
(see p. 14-10 for details)
050073
Send/read split lock set (0=OFF,
1=ON)
050074
Send/read tuner auto start set
(0=OFF, 1=ON)
050075
Send/read PTT tune set (0=OFF,
1=ON)
050076
Send/read transverter set
(0=OFF, 1=ON)
050077
Send/read transverter offset (see
p. 14-10 for details)
050078
Send/read RTTY mark frequency
(0=1275 Hz, 1=1615 Hz,
2=2125 Hz)
050079
Send/read RTTY shift width
(0=170 Hz, 1=200 Hz, 2=425 Hz)
050080
Send/read RTTY keying polarity
(0=Normal, 1=Reverse)
050081
Send/read PSK tone frequency
(0=1000 Hz, 1=1500 Hz,
2=2000 Hz)
050082
Send/read speech language
(0=English, 1=Japanese)
050083
Send/read speech speed (0=Slow,
1=Fast)
050084
Send/read S-level speech
(0=OFF, 1=ON)
050085
Send/read speech with a mode
switch operation (0=OFF, 1=ON)
050086
Send/read memo pad numbers
(0=5 ch, 1=10 ch)