Make sure the [POWER] switch is OFF before connect-
ing the DC power cable.
•
We recommend using Icom’s optional power supply
(PS-126: DC13.8 V/25 A).
D
Connecting the PS-126 power supply
Rear panel
GND
PS-126
Use the attached AC cable to con-
nect to AC outlet.
To
[DC 13.8V]
The transceiver needs followings:
•
DC 13.8 V (Capacity: 22 A and over)
•
A power supply with an over current protective line
and with a less voltage fluctuation or ripple
D
Connecting a non-Icom DC power supply
Connect the black DC power cable to the (–) Negative
terminal, and the red DC power cable to the (+) Positive
terminal.
Rear panel
GND
DC power socket
Fuse
holder
RED
BLACK
Stabilized power supply
AC outlet
OPC-1457
R
WARNING!
(About DC power supply)
•
Make sure DC power cable polarity is correct.
Red: Po terminal
Black: Negative – terminal
•
NEVER
cut the DC power cable between the DC
plug and fuse holder.
•
DO NOT
use unattached or undesignated DC pow-
er cable.
•
DO NOT
forcibly pull or bend the DC power cable.
Install the devices far enough from the place where
people might put things or step on the DC power
cable.