12
SCAN OPERATION
12-5
SCAN Speed
(Default: Fast)
Select the desired scan speed between slow and fast.
• Slow: The scan is slower.
• Fast: The scan is faster.
SCAN Resume
(Default: ON)
Set the Scan Resume function ON or OFF.
• OFF: When a signal is detected, the scan is can
-
celled.
• ON: When a signal is received during a scan, the
scan pauses for the set period of time in the
“Pause Timer” setting, and then resumes.
When the signal disappears, the scan resumes
after the set period of time in the “Resume Tim-
er” setting.
Pause Timer
(Default: 10 sec)
Select the scan Pause Timer.
When a signal is received, the scan pauses according
to this setting.
When the “SCAN Resume” is set to “OFF,” this setting
is invalid.
• 2 to 20 sec: When a signal disappears while pausing
the scan for 2 to 20 seconds (in 2 sec-
onds steps), the scan resumes accord-
ing to the setting in the Resume Timer.
• Hold:
When receiving a signal, the scan paus
-
es and resumes when it disappears, ac-
cording to the setting in Resume Timer.
Resume Timer
(Default: 2sec)
Select the scan Resume Timer.
When a received signal disappears, the scan resumes
according to this setting.
When the “SCAN Resume” is set to “OFF,” this setting
is invalid.
• 0 sec:
The scan resumes immediately after the
signal disappears.
• 1 to 5 sec: The scan resumes 1 to 5 seconds after
the signal disappears.
• Hold:
The scan remains paused according to
the Pause Timer, even if the signal disap-
pears.
- Rotate the Dial to resume the scan.
- When “Pause Timer” is set to 2 to 20
seconds, the scan resumes, according
to the “Pause Timer” setting.
MAIN DIAL (SCAN)
(Default: Up/Down)
Select the function of the Dial while scanning.
• OFF
: Rotating the Dial cancels the scan.
• Up/Down : Rotating the Dial changes the scanning
direction.
Scan Set mode (Continued)