484
IBM TotalStorage DS300 and DS400 Best Practices Guide
Figure 9-57 Initiator information
6. Reboot the server and verify after reboot that you see 4 drives in the device
manager and one multipath device.
IBM FAStT MSJ shows 4 targets and every target has one LUN. This is
correct.
DS400[A]# initiator manage RIOGRANDE-S3-(0) info
----[ Initiators ]---------------------------------------------------------
----[ Initiator 'RIOGRANDE-S3-(0)' ]---------------------------------------
WWN: 210000e08b17d774
Alias: RIOGRANDE-S3-(0)
ID: 4
Port access:
Port A0 Port A1 Port B0 Port B1
---------------------------------------------------------------------------
YES NO NO NO
LUN Mappings:
LUN logical [Capacity]
---------------------------------------------------------------------------
0 RIOGRANDE-BOOT [ 10.00GB]
DS400[A]# initiator manage RIOGRANDE-S3-(0) allow A1 B0 B1
Access allowed to initiator RIOGRANDE-S3-(0) on ports A1 B0 and B1
DS400[A]#
Summary of Contents for TotalStorage DS300
Page 2: ......
Page 20: ...2 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 28: ...10 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 226: ...208 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 228: ...210 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 240: ...222 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 450: ...432 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 581: ...Copyright IBM Corp 2006 All rights reserved 563 Part 4 Appendixes Part 4...
Page 582: ...564 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 638: ...620 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 640: ...622 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 648: ...630 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 664: ...646 IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 677: ...1 0 spine 0 875 1 498 460 788 pages IBM TotalStorage DS300 and DS400 Best Practices Guide...
Page 678: ......
Page 679: ......