Notes
This command runs a consistency check against a configuration database. All database records are
checked. Error data is written to a file in the data folder on disk automatically. You do not need to specify
an output file.
Executing a consistency check with the
diagnosticType
parameter set to a value other than filesystem
and with the
sourceLocation
parameter set to
onboard
can cause the operation to run for a long time.
This can have adverse effects on host I/O processing. This operation should be done only under direction
from the support organization.
Upon completion of the diagnostic test, the controller firmware returns one of these results:
v
Diagnosis completed without errors. No ZIP file created.
v
Diagnosis completed with errors. Refer to the ZIP file created at:
...\Install_dir\data\FirmwareUpgradeReports\timestamp_buildNo.zip
If the diagnostic test detects an inconsistency in the configuration database, the controller firmware
performs these actions:
v
Returns a description of the inconsistency
v
Saves a ZIP file containing raw binary data
The controller firmware saves the ZIP file to this location:
...\Install_dir\data\FirmwareUpgradeReports\timestamp_buildNo.zip
You can use the binary data to help determine the cause of the problem, or you can send the file
containing the binary data to a IBM Technical Support representative.
To stop the database configuration diagnostic test, use the
stop storageSubsystem configDbDiagnostic
command.
In addition, you can start the database configuration diagnostic test through the storage management
software GUI; however, you cannot stop the database configuration diagnostic test through the storage
management software GUI. If you want to stop a running diagnostic test, you must use the
stop
storageSubsystem configDbDiagnostic
command
Start Storage Subsystem Diagnostic Data Capture
This command produces a storage subsystem diagnostic data capture.
Syntax
start storageSubsystem ddc controller [(a|b)]
Parameters
Parameter
Description
controller
This parameter specifies the controller from which to
produce the diagnostic data capture. Valid controller
identifiers are a or b, where a is the controller in slot A,
and b is the controller in slot B. Enclose the controller
identifier in square brackets ([ ]). If you do not specify a
controller, the storage management software returns a
syntax error.
Chapter 3. Script Commands
3-305
Summary of Contents for System Storage DS3000
Page 599: ...Appendix A Examples of information returned by the show commands A 3...
Page 601: ...Appendix A Examples of information returned by the show commands A 5...
Page 603: ...Appendix A Examples of information returned by the show commands A 7...
Page 605: ...Appendix A Examples of information returned by the show commands A 9...
Page 607: ...Appendix A Examples of information returned by the show commands A 11...
Page 609: ...Appendix A Examples of information returned by the show commands A 13...
Page 611: ...Appendix A Examples of information returned by the show commands A 15...
Page 623: ...Appendix A Examples of information returned by the show commands A 27...
Page 625: ...Appendix A Examples of information returned by the show commands A 29...
Page 627: ...Appendix A Examples of information returned by the show commands A 31...
Page 651: ......
Page 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...