Parameters
Parameter
Description
cacheBackupDevice
The identifier for the cache backup device on which you
want to run the diagnostic tests. Valid cache backup device
identifiers are
1
,
2
,
3
,
4
or
5
.
v
1
for USB1 on the controller circuit board
v
2
for USB2 on the controller circuit board
v
3
for USB3 on the controller circuit board
v
4
for USB4 on the controller circuit board
v
all
for all of the USBs on the controller circuit board
Note:
If you have only one cache backup device, the all
identifier does not work. Enclose the identifier for the cache
backup device in square brackets ([ ]).
controller
The controller that has the cache backup device on which
you want to run the diagnostic tests. Valid controller
identifiers are
a
or
b
, where
a
is the controller in slot A, and
b
is the controller in slot B. Enclose the controller identifier
in square brackets ([ ]). If you do not specify a controller, the
storage management software returns a syntax error.
diagnosticType
The level of diagnostic testing that you want to run on the
cache backup device. You can run one of these levels of
testing:
basic
– This option validates the basic operation of the
ability of the cache backup device to store cache data. This
option determines these capabilities of the cache backup
device:
v
Whether the cache backup device is write protected or the
cache can write data to the device.
v
If the cache backup device is approaching its write cycle
limit.
extended
– This option enables you to run more
comprehensive diagnostic tests on the host interface card.
extendTestID
This parameter selects the extended test option that you
want to run.
If you choose the
extended
parameter, you also must also
use the
extendedTestID
parameter and one of the extended
test options.
Extended Test Option
Description
writePatterns
This option writes a predefined pattern of data in blocks to
the entire cache backup device. Each block that was written
is then read back, and the data is verified for integrity and
accuracy.
random
This option writes a random pattern to each flash block in
the cache backup device.
3-286
IBM System Storage DS3000, DS4000, and DS5000: Command Line Interface and Script Commands Programming Guide
Summary of Contents for System Storage DS3000
Page 599: ...Appendix A Examples of information returned by the show commands A 3...
Page 601: ...Appendix A Examples of information returned by the show commands A 5...
Page 603: ...Appendix A Examples of information returned by the show commands A 7...
Page 605: ...Appendix A Examples of information returned by the show commands A 9...
Page 607: ...Appendix A Examples of information returned by the show commands A 11...
Page 609: ...Appendix A Examples of information returned by the show commands A 13...
Page 611: ...Appendix A Examples of information returned by the show commands A 15...
Page 623: ...Appendix A Examples of information returned by the show commands A 27...
Page 625: ...Appendix A Examples of information returned by the show commands A 29...
Page 627: ...Appendix A Examples of information returned by the show commands A 31...
Page 651: ......
Page 652: ...Part Number 00W1466 Printed in USA GA32 0961 05 1P P N 00W1466...