background image

Hitachi Virtual Storage Platform G900

88-02-0x

Hardware Reference Guide

This document provides information about the system hardware components and the mechanical and
environmental specifications for the Hitachi Virtual Storage Platform G900 storage system.

MK-97HM85014-01
September 2018

Summary of Contents for 88-02-0 Series

Page 1: ... 0x Hardware Reference Guide This document provides information about the system hardware components and the mechanical and environmental specifications for the Hitachi Virtual Storage Platform G900 storage system MK 97HM85014 01 September 2018 ...

Page 2: ...rom authorized employees and other individuals and 2 Verifying that your data continues to be held retrieved deleted or otherwise processed in accordance with relevant laws Notice on Export Controls The technical data and technology inherent in this Document may be subject to U S export control laws including the U S Export Administration Act and its associated regulations and may be subject to ex...

Page 3: ...el LEDs without bezel 17 CBL controller rear panel LEDs 19 CBL controller power supply unit LEDs and connectors 19 Host Network and Drive Tray Ports and LEDs 20 Front end modules 20 10 Gbps iSCSI board LEDs and connectors optical 21 10 Gbps iSCSI board LEDs and connectors copper 21 8 Gbps 16 Gbps or 32 Gbps Fibre Channel 4 port board LEDs and connectors 23 16 Gbps Fibre Channel 2 port board LEDs a...

Page 4: ...ray rear panel 43 Chapter 4 Host port expansion chassis 45 Host port expansion chassis front panel bezel LEDs 45 PCIe switchboard 45 Host port expansion chassis fan 46 PCIe cable connector 47 Host port expansion chassis power supply 48 Chapter 5 Service processor 50 Service Processor Windows 10 Enterprise hardware specifications 50 Service processor description 51 SVP front panel 52 SVP rear panel...

Page 5: ...dix E Power distribution units for Hitachi Universal V2 Rack 108 Americas single phase PDU 1P30A 8C13 3C19UL P 108 Americas single phase PDU 1P30A 15C13 3C19UL P 109 Americas three phase PDU 3P30A 8C13 3C19UL P 109 Americas three phase PDU 3P30A 15C13 3C19UL P 110 Americas three phase PDU 3P30A 24C13 6C19UL P 111 APAC and EMEA single phase PDU 1P32A 9C13 3C19CE P 112 APAC and EMEA single phase PDU...

Page 6: ...e tray 124 Flash module drive tray 125 Dense intermix drive tray 126 CBL controller 127 Dense intermix drive tray power supply 127 CMA used to secure dense intermix drive tray 128 Battery 128 Host port expansion chassis 128 PCIe switch board 129 Appendix H Environmental notices 131 Appendix I Regulatory compliance 132 Contents Hitachi Virtual Storage Platform G900 Hardware Reference Guide 6 ...

Page 7: ...elopment Kit website http sourceforge net apps mediawiki tianocore index php title UDK2010 2004 Intel Corporation All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer Red...

Page 8: ...ITY OF SUCH DAMAGE Product version This document revision applies to VSP G900 firmware 88 02 0x or later Release notes Read the release notes before installing and using this product They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document Release notes are available on Hitachi Vantara Support Connect https knowledge hit...

Page 9: ...r output by the system Example pairdisplay g group For exceptions to this convention for variables see the entry for angle brackets Monospace Indicates text that is displayed on screen or entered by the user Example pairdisplay g oradb angle brackets Indicates variables in the following scenarios Variables are not clearly separated from the surrounding text or from other variables Example Status r...

Page 10: ... a hazardous situation which if not avoided could result in death or serious injury Conventions for storage capacity values Physical storage capacity values for example disk drive capacity are calculated based on the following values Physical capacity unit Value 1 kilobyte KB 1 000 103 bytes 1 megabyte MB 1 000 KB or 1 0002 bytes 1 gigabyte GB 1 000 MB or 1 0003 bytes 1 terabyte TB 1 000 GB or 1 0...

Page 11: ...fter the release of the product Getting help Hitachi Vantara Support Connect is the destination for technical support of products and solutions sold by Hitachi Vantara To contact technical support log on to Hitachi Vantara Support Connect for contact information https support hitachivantara com en_us contact us html Hitachi Vantara Community is a global online community for Hitachi Vantara custome...

Page 12: ...de the document title and number including the revision level for example 07 and refer to specific sections and paragraphs whenever possible All comments become the property of Hitachi Vantara Corporation Thank you Comments Preface Hitachi Virtual Storage Platform G900 Hardware Reference Guide 12 ...

Page 13: ...nt fails Adding and replacing components along with firmware upgrades can be conducted while the storage system is active and without interruption of data availability to the hosts A hot spare drive can be configured to replace a failed data drive automatically securing the fault tolerant integrity of the logical drives Self contained hardware based RAID logical drives provide maximum performance ...

Page 14: ...ID 6 including 14D 2P Provides data security by transferring data to cache flash memory at the time of a power outage Scalability and versatility Small form factor drive tray DBS Up to 24 2 5 inch HDDs or flash drives can be installed 2U size Large form factor drive tray DBL Up to 12 3 5 inch HDDs can be installed 2U size High density intermix drive tray DB60 Up to 60 3 5 inch HDDs can be installe...

Page 15: ...h LED indicators for monitoring its operating conditions and notifying possible component replacement CBL controller chassis The controller chassis houses controllers backup fan modules and power supplies The chassis also includes specific functional LEDs located on the front and rear of controller to provide its operating status The following table lists the controller board specifications Compon...

Page 16: ... not blink even if the following failure service information messages SIM are issued 452xxx 462xxx 3077xx 4100xx and 410100 LED might turn off during user maintenance 4 ALARM LED Off Normal operation Red Processor failure system might be down For assistance contact customer support https support hitachivantara com en_us contact us html 5 POWER ON OFF main switch Powers the storage system CBL contr...

Page 17: ...bes the definitions of the CBL controller front panel LEDs Number Item Description 1 POWER ON OFF main switch Powers the storage system 2 POWER READY WARNING and ALARM LEDs Note When System Option Mode 1097 is set to ON the WARNING LED does not blink even if the following failure service information messages SIM are issued 452xxx 462xxx 3077xx 4100xx and 410100 3 Controllers Controller 1 bottom an...

Page 18: ... unit of the controller Amber LAN reset switch was pressed 9 LAN RST switch Use only when instructed by customer support 10 STATUS LED for BKMF Green Charging of the battery in the backup module is complete Red Backup module can be removed Blink red one time Main battery failure Blink red two times Backup battery failure Blink red three times Both batteries failed or preventive maintenance replace...

Page 19: ... following table describes the definitions of the CBL controller rear panel LEDs Number Item 1 Power supply unit 2 Front end module 3 Back end module 4 LAN blade CBL controller power supply unit LEDs and connectors The following table lists the definitions of the CBL controller power supply unit LEDs and connectors CBL controller rear panel LEDs Chapter 2 System controller Hitachi Virtual Storage ...

Page 20: ...e equipped with specific interfaces for connecting powering configuring and managing the storage system The component LEDs display the operating status of the storage system Front end modules The following front end modules are available for the controllers The LEDs display the operating status of the module Host Network and Drive Tray Ports and LEDs Chapter 2 System controller Hitachi Virtual Sto...

Page 21: ...ly 2 PORT LED Red Small form factor pluggable can be removed Blue Normal link status Blink blue Front end module is in communication status 3 ISCSI connectors Connect to Ethernet cables 10 Gbps iSCSI board LEDs and connectors copper 10 Gbps iSCSI board LEDs and connectors optical Chapter 2 System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide 21 ...

Page 22: ...nk Green 10 Gbps link Off No link connection 3 PORT LED Green Link connection is established Blinking Communication is in progress Off No link connection or not ready to communicate 4 ISCSI connectors Connect to Ethernet cables 10 Gbps iSCSI board LEDs and connectors copper Chapter 2 System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide 22 ...

Page 23: ...l form factor pluggable can be removed Blue Normal link status at 8 Gbps Green Normal link status at 2 Gbps or 4 Gbps Table 2 32 Gbps 16 Gbps Fibre Channel Number Item Description 1 Fibre Channel connectors Connect to Fibre Channel cables 2 STATUS LED Green Front end module is in power on state Red Front end module can be removed safely 8 Gbps 16 Gbps or 32 Gbps Fibre Channel 4 port board LEDs and...

Page 24: ... 32 Gbps Fibre Channel ports left to right Port 1 Port 2 Port 3 Port 4 CHB 1A 1A 3A 5A 7A CHB 1B 1B 3B 5B 7B CHB 1C 1C 3C 5C 7C CHB 1D 1D 3D 5D 7D CHB 1E 1E 3E 5E 7E CHB 1F 1F 3F 5F 7F CHB 1G 1G 3G 5G 7G CHB 1H 1H 3H 5H 7H CHB 2A 2A 4A 6A 8A CHB 2B 2B 4B 6B 8B CHB 2C 2C 4C 6C 8C CHB 2D 2D 4D 6D 8D CHB 2E 2E 4E 6E 8E CHB 2F 2F 4F 6F 8F CHB 2G 2G 4G 6G 8G 8 Gbps 16 Gbps or 32 Gbps Fibre Channel 4 po...

Page 25: ...end module is in the power on state Red Front end module can be removed safely 2 PORT LED Red Small form factor pluggable can be removed Blue Normal link status at 16 Gbps Green Normal link status at 4 Gbps or 8 Gbps 3 Fibre Channel connectors Connect to Fibre Channel cables 16 Gbps Fibre Channel 2 port board LEDs and connectors Chapter 2 System controller Hitachi Virtual Storage Platform G900 Har...

Page 26: ...1B 3B CHB 1C 1C 3C CHB 1D 1D 3D CHB 1E 1E 3E CHB 1F 1F 3F CHB 1G 1G 3G CHB 1H 1H 3H CHB 2A 2A 4A CHB 2B 2B 4B CHB 2C 2C 4C CHB 2D 2D 4D CHB 2E 2E 4E CHB 2F 2F 4F CHB 2G 2G 4G CHB 2H 2H 4H PCIe module PCIe module Chapter 2 System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide 26 ...

Page 27: ...ff PCIe module can be removed safely 2 Link Green PCIe is Gen 3 8 Gbps and is linked up normally Off PCIe is not linked up PCIe cable might not be connected If a PCIe cable is connected it can be removed safely PCIe module Chapter 2 System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide 27 ...

Page 28: ...4 LAN 1 Maintenance LAN port used by service personnel 5 LAN ALARM LED Red LAN blade can be removed 6 Uninterruptible power supply UPS port N A Back end module LEDs and connectors The back end module LEDs display the operating status of the module LAN blade LEDs and connectors Chapter 2 System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide 28 ...

Page 29: ...ack end module can be removed safely 2 PORT LED Blue Link status is normal 3 PATH 0 connector Connect to a drive tray 4 PATH 1 connector Connects to a drive tray Back end module LEDs and connectors Chapter 2 System controller Hitachi Virtual Storage Platform G900 Hardware Reference Guide 29 ...

Page 30: ...e across all host connection ports conventional hard disk drives HDD are not included or configurable with all flash arrays Small form factor drive tray DBS The following describes the physical specifications of the small form factor drive tray Name Model name Height Number of drive slots Drive type DBS DW F800 DBSC 2U 88 2 mm 24 2 5 inch SFF SFF with front panel bezel Number Item Description 1 PO...

Page 31: ...ezel Number Item Description 1 POWER READY and LOCATE LEDs Green Drive tray is powered on Green Drive tray is operational Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 2 ALM LED Red Drive stopped due to a failure and can be replaced 3 ACT LED Green Normal operation SFF front panel without bezel Chapter 3 Drive trays Hitachi Virtual Storage Pl...

Page 32: ... Description 1 ENC N A 2 POWER LED Green ENC is in the power on state 3 Locate LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 ALARM LED Red ENC can be replaced 5 PATH IN LED Blue IN side port is linked up 6 PATH IN connector Connects to a controller or drive tray SFF rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform G900 ...

Page 33: ...it can be replaced 14 RDY LED Green Normal operation AC power supply unit LEDs and connectors Both SFF and LFF drive trays are equipped with AC power supply units The AC power supply units include LEDs to display its operating status Number Item Description 1 RDY LED Green Normal operation 2 ACI IN LED Green AC input is operating normally 3 ALM LED Red Power supply unit can be replaced AC power su...

Page 34: ...nt panel bezel Number Item Description 1 POWER LED Green Drive tray is powered on 2 READY LED Green Drive tray is operational 3 Locate LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key Large form factor drive tray DBL Chapter 3 Drive trays Hitachi Virtual Storage Platfor...

Page 35: ...ance utility 2 ACT LED Green Normal operation Blink green Drive is being accessed 3 ALM LED Red Drive stopped due to a failure and can be replaced 4 Large form factor drives The twelve 3 5 inch large form factor drives are positioned horizontally The slots are organized in the following order 8 9 10 11 4 5 6 7 0 1 2 3 LFF front panel without bezel Chapter 3 Drive trays Hitachi Virtual Storage Plat...

Page 36: ... IN connector Connects to a controller or drive tray 7 PATH OUT LED Blue OUT side port is linked up 8 PATH OUT connector Connects to a drive tray 9 Console This port is reserved 10 Power supply unit N A 11 Receptacle Connects to the power cable provided with the storage system 12 AC IN LED Green Normal operation 13 ALM LED Red Power supply unit can be replaced 14 RDY LED Green Normal operation LFF...

Page 37: ...en AC input is operating normally 3 ALM LED Red Power supply unit can be replaced Flash module drive tray DBF The following describes the physical specifications of the flash module drive tray Name Model name Height Number of drive slots Drive type DBF DW F800 DBF 2U 87 mm 12 Flash module drive FMD FMD with front panel bezel AC power supply unit LEDs and connectors Chapter 3 Drive trays Hitachi Vi...

Page 38: ... Can be turned on or turned off by the maintenance utility 4 Lock Locks and unlocks the front panel bezel by using the supplied key FMD front panel without bezel Number Item Description 1 2 ACT LED Green Normal operation Blink Drive is being accessed FMD front panel without bezel Chapter 3 Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide 38 ...

Page 39: ... is only printed on some types of FMDs 3 POWER READY and LOCATE LEDs Green Drive tray is powered on Green Drive tray is operational Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 4 Flash module drives Twelve flash module drives Slots are organized the following way 9 10 11 6 7 8 3 4 5 0 1 2 FMD front panel without bezel Chapter 3 Drive trays H...

Page 40: ...e port is linked up 6 PATH IN connector Connects to a controller or drive tray 7 PATH OUT LED Blue OUT side port is linked up 8 PATH OUT connector Connects to a drive tray 9 Console This port is reserved 10 Receptacle Connects to the power cable provided with the storage system 11 Three LEDS top to bottom RDY LED AC IN LED Green Power supply unit is operating normally FMD rear panel Chapter 3 Driv...

Page 41: ...f the high density drive tray Name Model name Height Number of drive slots Drive type DB60 DW F800 DB60C 4U 176 mm 60 3 5 inch LFF Dense intermix drive tray with front panel bezel Number Item Description 1 POWER LED Green Drive tray is powered on 2 READY LED Green Drive tray is operational High density intermix drive tray DB60 Chapter 3 Drive trays Hitachi Virtual Storage Platform G900 Hardware Re...

Page 42: ...s the front panel bezel by using the supplied key Dense intermix drive tray display LEDs Number Item Description 1 ACT Green Normal operation Blink Drive is being accessed 2 ALM LED Red Drive stopped due to a failure and can be replaced Dense intermix drive tray display LEDs Chapter 3 Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide 42 ...

Page 43: ...l Number Item Description 1 Power supply unit N A 2 RDY LED Green Normal operation 3 AC IN LED Green Normal operation 4 ALM LED Red Power supply unit can be replaced 5 Receptacle Connects to the power cable provided with the storage system 6 ENC N A 7 PATH OUT LED Blue OUT side port is linked up 8 PATH OUT connector Connects to a drive tray Dense intermix drive tray rear panel Chapter 3 Drive tray...

Page 44: ...s port is reserved 12 ALARM LED Red ENC can be replaced 13 Locate LED Amber Indicates the location of the chassis Can be turned on or turned off by the maintenance utility 14 POWER LED Green ENC is in the power on state Dense intermix drive tray rear panel Chapter 3 Drive trays Hitachi Virtual Storage Platform G900 Hardware Reference Guide 44 ...

Page 45: ...s iSCSI and FC cards For more information contact customer support Host port expansion chassis front panel bezel LEDs Number Item Description 1 POWER LED Green Host port expansion is turned on Amber PCIe module is turned on Off PCIe module is turned off 2 Safety lock Lock or unlock the front bezel PCIe switchboard Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware...

Page 46: ...is powered on Red PCIe switchboard can be replaced safely Off PCIe switchboard is powered off Host port expansion chassis fan Host port expansion chassis fan Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware Reference Guide 46 ...

Page 47: ...scription 1 ALM LED Red Fan failure has occurred Off Normal operation PCIe cable connector PCIe cable connector Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware Reference Guide 47 ...

Page 48: ...o link down and cables Cables can be removed safely Off Basic PCIe is normal or not set 4 Link Option LED Green Option PCIe Gen 3 0 8 Gbps is linked up normally Off Option PCIe is not linked up PCIe cable might not be connected If a cable is connected it can be removed safely 5 InAct Option LED Amber Option PCIe status changed from link up to link down and cables Cables can be removed safely Off O...

Page 49: ...pansion chassis power supply can be replaced safely Green Normal operation 2 AC IN LED Blue AC input is normal Host port expansion chassis power supply Chapter 4 Host port expansion chassis Hitachi Virtual Storage Platform G900 Hardware Reference Guide 49 ...

Page 50: ... Hypervisor support for Gx00 Fx00 report at https support hitachivantara com en_us interoperability html Service Processor Windows 10 Enterprise hardware specifications The following table lists the hardware specifications for the service processor Windows 10 Enterprise provided by Hitachi Vantara Item Specification Dimensions Height 1 7 inches 43 mm Width 17 2 inches 437 mm Depth 9 8 inches 249 m...

Page 51: ... the controllers and the IP network are configured as a bridge The SVP can be addressed using the default IP address 192 168 0 15 In the unlikely event you cannot connect to the SVP using the default IP address use the following emergency login http default SVP IP address dev storage model number system serial number emergency do For example Storage system model number Storage system serial number...

Page 52: ...s equipped with LEDs a reset button and a power button Table 3 SVP Windows 10 Enterprise front panel Item Description 1 LED Left to Right N A LAN card 2 LAN card 1 Hard drive System standby power 2 Reset button 3 Power button SVP rear panel The only ports used at the rear panel of the physical SVP are the power socket and the four LAN ports The following ports connect to your IP network the manage...

Page 53: ... network has BPDU enabled to prevent loops connect the user LAN port on controllers 1 and 2 to an Ethernet switch that is also connected to the LAN1 port on the SVP Note After the Initial Startup Wizard is complete the SVP can be used in non bridge mode In this mode the cables can be removed from SVP ports LAN3 and LAN4 and attached to switches For more information contact customer support SVP rea...

Page 54: ...blinking status 2 Release the main switch and the POWER LED returns to solid green after blinking for approximately three seconds The power off process begins The process takes approximately 18 minutes or longer depending on the amount of data that needs to be written The POWER LED is solid green during the powering off process The POWER LED changes from green to amber when the process is complete...

Page 55: ... sudden power failure In these cases follow the normal power down procedure If not the battery might reach its lifespan earlier than expected and become unusable within three years When replacing the battery follow the given procedure for disposing a used battery Replacement period The battery lifetime intake temperature is 30 degrees C or less in the standard environment is as shown below Storage...

Page 56: ...to release the latch and remove the SAS cable 2 To remove a LAN cable push the top of the LAN cable connector 1 to release the latch and remove the LAN cable 2 Removing cables Chapter 6 Maintaining the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 56 ...

Page 57: ...VSP G900 parts list The VSP G900 includes the following standard and optional components Table 5 CBL controller components Model number Part description Quantity DW850 CBL 4U chassis 1 Power supply unit 2 LAN board LAN UPS 2 Backup module BKM 8 Front bezel 4U 1 Binder 1 SAS cable label 2 DW F800 RRCB Rail kit 1 DW F800 BAT Battery 6 Appendix A Storage system parts list Hitachi Virtual Storage Plat...

Page 58: ...ront end module 32 16 Gbps 4port FC 2 20 DW F800 1HP8 PCIe switchboard also known as a channel board 2 DW F800 PC1F PCIe cable 1 5m 2 DW F800 BS12G Back end module also known as disk board 0 8 DW F800 BS12GE Back end module with encryption 0 8 DW F800 1PS16 SFP for 16 Gbps Shortwave 0 80 DW F800 1PL16 SFP for 16 Gbps Longwave 0 80 DW F800 1PL32 SFP for 32 Gbps Longwave 0 80 DW F800 BAT Battery 0 6...

Page 59: ...2JCMC 1 2 TB 2 5 inch 10kmin 12 Gbps SAS drive 0 24 DKC F810I 2R4JGM 2 4 TB 2 5 inch 10kmin 12 Gbps SAS drive 0 24 DKC F810I 960MGM 960 GB MLC 12 Gbps SFF flash drive 0 24 DKC F810I 1R9MGM 1 9 TB MLC TLC 12 Gbps SFF flash drive 0 24 DKC F810I 3R8MGM 3 8 TB MLC TLC 12 Gbps SFF flash drive 0 24 DKC F810I 7R6MGM 7 6 TB TLC 12 Gbps SFF flash drive 0 24 DKC F810I 15RMGM 15 TB TLC 12 Gbps SFF flash driv...

Page 60: ... drive 0 12 Table 11 DBF drive tray components Model number Part description Quantity DW F800 DBF 2U chassis 1 ENC 2 Power supply unit 2 Front bezel 2U 1 DW F800 RRDBF Rail kit 1 Table 12 DBF optional drive tray components Model number Part description Quantity DKC F810I 3R2FN 3 5 TB MLC 12 Gbps flash module drive 0 12 DKC F810I 7R0FP 7 TB MLC TLC 12 Gbps flash module drive 0 12 DKC F810I 14RFP 14...

Page 61: ...ble 14 DB60 drive tray optional components Model number Part description Quantity DKC F810I 1R2J7MC 1 2 TB 2 5 inch 10kmin 12 Gbps SAS drive 0 60 DKC F810I 2R4J8M 2 4 TB 2 5 inch 10kmin 12 Gbps SAS drive 0 60 DKC F810I 6R0HLM 6 TB 3 5 inch 7 2kmin 12 Gbps SAS drive 0 60 DKC F810I 10RHLM 10 TB 3 5 inch 7 2kmin 12 Gbps SAS drive 0 60 VSP G900 parts list Appendix A Storage system parts list Hitachi V...

Page 62: ...0 SVP P Service processor Windows 10 Enterprise 1 Drive tray and drive configuration The following table lists the supported maximum mountable drive trays and data drives for the VSP G900 storage system Controller chassis Number of mountable drive trays Maximum number of mountable drives Drive trays Maximum SAS drive Solid state drive Flash module drive FMD CBL DBS 48 1 152 1 152 N A DBL 48 576 N ...

Page 63: ...2 pole power cable with grounding terminal AC 250 V 13 A or 15 A A F6516 P620 Power cable for PDU 1 A F6516 P630 Power cable for PDU 1 Table 18 SAS cables Model number Specification DW F800 SCQ1 1 m SAS cable including omega clip 2 DW F800 SCQ1F 1 5 m SAS cable including omega clips 2 DW F800 SCQ3 3 m SAS cable including omega clips 2 DW F800 SCQ5 5 m SAS cable including omega clips 2 DW F800 SCQ1...

Page 64: ...LC optical cable for optical A 6515 HM10L 10 m LC LC optical cable for optical A 6515 HM20L 20 m LC LC optical cable for optical A 6515 HM30L 30 m LC LC optical cable for optical A 6515 HM50L 50 m LC LC optical cable for optical A 6515 HM100L 100 m LC LC optical cable for optical A 6515 HM200L 200 m LC LC optical cable for optical A 6515 HM300L 300 m LC LC optical cable for optical A 6515 JM5L 5 m...

Page 65: ...number Specification A 6515 JM300L 300 m LC LC optical cable for optical Data and power cable model list Appendix A Storage system parts list Hitachi Virtual Storage Platform G900 Hardware Reference Guide 65 ...

Page 66: ...IA unit 2 4U Heat output W 338 W Power consumption VA 363 VA Air flow m3 min 3 6 0 m3 min Notes 1 The start up time might be longer in proportion to the number of drive trays connected With a maximum configuration 1 controller chassis and 19 drive trays start up time is approximately 8 minutes 2 Can be mounted on the RKU rack For the mounting special rails for the rack and decoration panels are re...

Page 67: ...B60 36 kg Start up time min 1 DBS 5 to 10 min DBL DBF DB60 Required height EIA unit 2 DBS 2U DBL DBF DB60 4U Heat output W DBS 116 W DBL 124 W DBF 120 W DB60 184 W Power consumption VA DBS 126 VA DBL 144 VA DBF 130 VA DB60 191 VA Air flow m3 min 3 DBS 2 2 m3 min DBL 2 2 m3 min DBF 1 6 m3 min VSP G900 mechanical specifications Appendix B System specifications Hitachi Virtual Storage Platform G900 H...

Page 68: ... drive trays start up time is approximately 8 minutes 2 Can be mounted on the RKU rack For the mounting special rails for the rack and decoration panels are required separately depending on the number of the mounted storage systems 3 The value is at maximum level VSP G900 mechanical specifications Appendix B System specifications Hitachi Virtual Storage Platform G900 Hardware Reference Guide 68 ...

Page 69: ... 5 inch SFF SSD 15 766 TiB Using 14 TB FMD 7 372 TiB Maximum mountable quantity unit 1 DBS 24 total per chassis 1 152 maximum per system DBL 12 576 DBF 12 576 DB60 60 1 140 Maximum number of spare drives2 DBS 64 DBL DB60 DBF Note 1 When mounting storage system and mixing DBS DBL DBF and DB60 drive trays the maximum mountable quantity unit may vary 2 Available as spare or data disks Host interface ...

Page 70: ...ports With CHBB installed 16 32 Gbps FC Optical 80 10 Gbps iSCSI Optical 40 10 Gbps iSCSI Copper 40 Transferred block size bytes 512 Maximum number of hosts via FC switch 255 Maximum number of hosts via network switch 255 Battery life Storage system intake temperature CBL Up to 75 2º F 24º C 5 years Up to 86º F 30º C 5 years Up to 93 2º 34º C 4 years Up to 104º 40º C 3 years VSP G900 mechanical sp...

Page 71: ...D6 RAID 5 or RAID 1 provides redundancy and enhances data reliability However there is still a possibility of losing data caused by unforeseeable hardware or software failure Users should always follow recommended best practices and back up all data Internal logic specifications CBL Item Specification Control memory Flash memory 32 MB L3 cache memory 4 MB SDRAM 1 GB Data assurance method Data bus ...

Page 72: ...00mA 1min Insulation resistance DC 500 V 10 MΩ or more Electrical specifications The electrical input power specifications for the storage systems are described in the following table Item Controller Drive tray Input voltage operable voltage range V AC 200 240 6 11 SFF LFF FMD and dense intermix drive tray AC 200 240 6 11 Frequency Hz 50 60 1 Number of phases cabling Single phase with protective g...

Page 73: ... or less Notes 1 The power current of Nx2 described in this table is required for a single power unit 2 If one power unit fails another power unit requires electric current for the two power units Therefore plan the power supply facility so that the current carrying capacity for one power unit can provide the total capacity for two power units 3 This table shows the power requirement 100 V or 200 ...

Page 74: ... to 122 F 10 C to 50 C 14 F to 122 F 10 C to 50 C 14 F to 122 F 10 C to 50 C Transport storage 22 F to 140 F 30 C to 60 C 22 F to 140 F 30 C to 60 C 22 F to 140 F 30 C to 60 C Temperature change rate C h 10 C or less State Controller FMD tray Operating 50 F to 104 F 10 C to 40 C DKC F810I 1R6FN 3R2FN 6R4FN 7R0FP 14RFP drive is installed 50 F to 104 F 10 C to 40 C Non operating 14 F to 122 F 10 C t...

Page 75: ...esonance point 10 Hz or less Non operating m s2 5 0 or less at 5 Hz to 300 Hz no damage to product 9 8 1 0 G Ensure own safety with fall prevention Within 5 seconds resonance point 10 Hz or less Transport packed m s2 5 0 or less Impact State CBL controller and drive trays Operating m s2 20 or less 10 ms half sine wave Non operating m s2 50 or less 10 ms half sine wave Transport packed 80 or less E...

Page 76: ... 60 to 12 000 Note 1 Meets the highest allowable temperature conditions and complies with ASHRAE American Society of Heating Refrigerating and Air Conditioning Engineers 2011 Thermal Guidelines Class A3 The maximum value of the ambient temperature and the altitude is from 40ºC at an altitude of 950m 3000 feet to 28ºC at an altitude of 3050m 1000 feet The allowable ambient temperature is decreased ...

Page 77: ...nes Class A2 The maximum value of the ambient temperature and the altitude is from 35ºC at an altitude of 950m 3000 feet to 28ºC at an altitude of 3050m 1000 feet The allowable ambient temperature is decreased by 1ºC for every 300m increase in altitude above 950m Gaseous contaminant Avoid areas exposed to corrosive gas and salty air State Controller FMD DBS DBL and DB60 drive trays Operating Gaseo...

Page 78: ...1 5m in the rack Measurement position 1m away from the front rear left or right side of the storage system and 1 5m high at four points Measurement value Energy average value of the four points front rear left and right The recommendation is to install the storage system in a computer room in a data center It is possible to install the storage system in a general office however take measures again...

Page 79: ...environment or if a failure occurs in the system 2 Sound pressure level LA changes from 66 dB or 75 dB according to the ambient temperature drive configuration and operating status Maximum volume can reach 79 dB during maintenance procedure for a failed ENC or power supply 3 Acoustic power level LwA measured by the ISO 7779 standard is 7 2 B This value changes from 7 2 B to 8 1 B according to the ...

Page 80: ...Level State Condition Operating Recommended 90 dB or less Note Fire suppression systems and acoustic noise Some data center inert gas fire suppression systems when activated release gas from pressurized cylinders that moves through the pipes at very high velocity The gas exits through multiple nozzles in the data center The release through the nozzles could generate high level acoustic noise Simil...

Page 81: ...urces such as emergency sirens 4 If it can be safely done without risk of personal injury shut down the storage systems to avoid data loss and damages to the hard disk drives in the storage systems Damage to the hard disk drives from fire suppression systems or pneumatic sirens will void the hard disk drive warranty Mechanical environmental conditions Item Operating Non operating Guaranteed value ...

Page 82: ...ory capacity required for adding shard memory function vary depending on storage system models Software Items affected by shared memory capacity ShadowImage TrueCopy Universal Replicator global active device The number of pairs that can be created For more information refer to the specific software user guide Volume Migration Volume Migration V2 The number of migration plans that can be executed c...

Page 83: ...unt of shared memory function to shared memory capacity Table 21 Shared memory function and shared memory capacity Shared Memory Function VSP G900 Base 108 5 GiB Extension1 124 5 GiB Extension2 140 5 GiB Extension3 156 5 GiB Table 22 Minimum cache memory capacity required for shared memory function Shared Memory Function VSP G900 Base 256 GiB Extension1 256 GiB Extension2 256 GiB Extension3 256 Gi...

Page 84: ...i Command Suite or Hitachi Storage Advisor Allow communication to the storage system from the SVP TCP IP port assignments When you install your storage system default ports must be opened to allow for incoming and outgoing requests Review the following ports before you install the storage system to avoid conflicts between the TCP IP port assignments used by the storage system and those used by oth...

Page 85: ...rt that Device Manager Storage Navigator uses refer to the Device Manager Storage Navigator online help 5989 Used by SMI S 10995 TCP Device Manager Storage Navigator and Hitachi suite components 23015 Used for Web browser communications 23016 Used for Web browser communications via SSL 28355 TCP Device Manager Storage Navigator Secure 31001 Used for communication by Hitachi Command Control Interfa...

Page 86: ...ssLoade r RMI 51099 No RMIClassLoade rHttps RMI SSL 5443 No RMIIFRegist RMI 1099 No PreRMIServer RMI 51100 513551 No Automatic allocation 88 02 0x xx 00 or later DKCManPrivate RMI 11099 N A 88 02 0x xx 00 or later SMI S SLP SLP 427 Yes only if SMI S is not used SMIS_CIMOM SMI S 5989 62441 Yes only if SMI S is not used 88 02 0x xx 00 or later Automatic allocation 88 02 0x xx 00 or later CommonJetty...

Page 87: ...ts available for host connections vary based on the controller model Fibre Channel SFP adapters are used to connect to your Fibre Channel switch and hosts iSCSI ports come in optical and copper RJ 45 interfaces and are used to connect to your Ethernet switch and hosts Each controller also has A SAS port for connection to an external drive tray An RJ 45 10 100 1000 bps user LAN port for performing ...

Page 88: ...on the same network segment as the SVP and storage system Note The SVP running Windows 10 operating system does not provide a way to disable Spanning Tree Protocol STP If your network has BPDU enabled to prevent loops connect the user LAN port on controllers 1 and 2 to an Ethernet switch instead of connecting them to SVP LAN 3 and LAN 4 ports Virtual SVP connectivity requires all of the following ...

Page 89: ...red for storage system installation vary according to the specific storage system and network configuration Fibre Channel and iSCSI cables are used to connect the controllers to a switch or host Serial attached SCSI SAS cables are used to connect drive trays to controllers and other drive trays Appendix D Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide 89 ...

Page 90: ...ect the iSCSI 10 Gb RJ 45 ports on each controller to a host computer direct connection or to several host computers via an Ethernet switch SAS SAS optical Connects the controller to a drive tray or a drive tray to another drive tray Two SAS cables are provided with each drive tray Ethernet RJ 45 Four shielded Category 5e or 6a Ethernet cables are required for connecting the SVP to the controllers...

Page 91: ...orts Fiber Channel connections to hosts For details about configuring FC host connections see the Provisioning Guide Note Due to high speed serial data transfer via Fibre Channel use high quality FC cables that comply with the Fibre Channel PH standard The following figure shows FC direct connection and FC connection through a switch Fibre Channel cables Appendix D Data and power cables Hitachi Vi...

Page 92: ...Gbps 984 25 ft 300 m 1640 4 ft 500 m 3280 8 ft 10 km 4 Gbps 493 ft 150 m 1246 72 ft 380 m 1312 3 ft 400 m 8 Gbps 164 04 ft 50 m 493 ft 150 m 623 36 ft 190 m 16 Gbps 114 8 ft 35 m 328 08 ft 100 m 410 1 ft 125 m 32 Gbps 65 62 ft 20 m 229 7 ft 70 m 328 08 ft 100 m Fibre Channel cables Appendix D Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide 92 ...

Page 93: ...lent to DXLC 2P PC xxM GC50 125 2SR OMx 50 125 μm 62 5 125 μm Multimode Wavelength 850 nm LC connector LC connector LC LC cable longwave DXLC 2PS SPC xxM SMC 10 125 2SR 9 125 μm Singlemode Wavelength 1300 nm The following figure shows the connector used for optical interfaces Fibre Channel cables Appendix D Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide 93 ...

Page 94: ...ions to hosts For details about configuring iSCSI host connections see the Provisioning Guide Cable specifications for iSCSI optical interface Cable type Interface Cable mode name Nominal Cable Connector One side Other side LC LC cable Optical Equivalent to DXLC 2P PC xxM GC50 125 2SR OMx 50 125 mm Multimode Wavelength 850 nm LC connector LC connector iSCSI cables Appendix D Data and power cables ...

Page 95: ...tor that connects the storage system optical iSCSI ports LC connector type Connector type LC duplex receptacle connector Interval 6 25 mm flat type two rows Cable specifications for 10 Gbps iSCSI copper interface iSCSI cables Appendix D Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide 95 ...

Page 96: ...bps 1000BASE T STP use an STP cable that suppresses radio noise RJ 45 Category 6a LAN cable 50 m 10 Gbps 10GBASE T STP use an STP cable that suppresses radio noise RJ 45 The following figure shows a 10 Gbps iSCSI cable iSCSI cables Appendix D Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide 96 ...

Page 97: ... RFC 1231 MIB II RFC 1757 RMON RFC 1901 SNMPv2 iSCSI specifications Item Specification Comments iSCSI target function Supported N A iSCSI target function Supported TrueCopy only iSCSI ports 2 per interface board VSP Gx00 models Maximum 32 per iSCSI system Connection methods Direct and switch connections Host connections 255 maximum per iSCSI port With Linux software initiator the maximum number de...

Page 98: ...k aggregation Not supported N A Tagged VLAN Supported N A IPv4 Supported N A IPv6 Supported Note the following precautions When iSCSI Port IPv6 is set to Enabled if the IPv6 global address is set to automatic the address is determined by acquiring a prefix from an IPv6 router If the IPv6 router does not exist in the network the address cannot be determined As a result an iSCSI connection might be ...

Page 99: ...e network equipment preventing the storage system from communicating through the new port number iSCSI name Both iqn3 and eui4 types are supported The unique iqn value is automatically set when a target is made iSCSI name is configurable Error recovery level 0 zero Error recovery by retrying from host Does not support Level 1 and Level 2 Header digest Supported Detects header error or data error w...

Page 100: ...1 HiCommand Dynamic Link Manager Pass switching is achieved Not supported on Windows Vista and Windows 7 operating systems 2 IP Security Authentication and encryption of IP packets The storage system does not support IPsec 3 iqn iSCSI Qualified Name The iqn consists of a type identifier iqn a date of domain acquisition a domain name and a character string given by the individual who acquired the d...

Page 101: ...nded bend radius The following table provides general guidelines for minimum bend radius values but you should consult the recommendation of your cable manufacturer Cable type Minimum bend radius values Fibre Channel 40 mm 1 73 inch iSCSI optical 40 mm 1 73 inch Category 5 Ethernet Four times the outside diameter of the cable SAS 40 mm 1 73 inch Managing cables Appendix D Data and power cables Hit...

Page 102: ...e cables over time Therefore do not allow cables to sag through gaps in your supports Place drop points in your supports that permit cables to reach racks without bending or pulling Unintentional unplugging or unseating of a power cable can have a serious impact on the operation of an enterprise storage system Unlike data cables power connectors do not have built in retention mechanisms to prevent...

Page 103: ...vides a variety of power cables that facilitate using storage systems around the world Hitachi power cables meet the safety standards for the country for which they are intended Power cable assemblies For information about racks and power distribution units PDUs refer to the Hitachi Universal V2 Rack Reference Guide Hitachi power cables consist of three parts Plug Male connector for insertion into...

Page 104: ...00 240 10 16 CEI 23 50 Italy 200 240 10 16 CEI 23 50 7 Argentina 200 240 10 15 IRAM 2073 Australia 200 240 10 15 AS 3112 China 200 240 10 16 GB 1002 New Zealand 200 240 10 15 AS 3112 8 Denmark 200 240 10 DK 2 5 Israel 200 240 10 16 SI 32 94 Europe 200 240 CEE 7 7 105 India 200 240 6 16 IS 1293 South Africa 200 240 10 16 SABS 164 11 Switzerland 200 240 10 SEV 1011 126 International 200 240 20 IEC 3...

Page 105: ...erland for a true 16 A application 7 4 wire three phase and earth Physical variations connector size and color indicate amperage rating 8 5 wire three phase earth and neutral Physical variations connector size and color indicate amperage rating AC connections The following table shows and describes the types of AC connections on your storage system Description Receptacle Input rating Reference sta...

Page 106: ...t rating Reference standards BS 1363 200V 240V 5 BS 1365 3 IEC 83 AS 3112 200V 240V 6 AS C112 Cable and connector AC connections Appendix D Data and power cables Hitachi Virtual Storage Platform G900 Hardware Reference Guide 106 ...

Page 107: ... any given time the voltage across the hot and neutral conductors can be anywhere between its peak maximum and zero Electrical conductors must be large to meet high amperage requirements Three phase power uses three cycles that are 120 degrees out of phase which never allows the voltage to drop to zero The more consistent voltage derived from the three hot conductors results in smoother current fl...

Page 108: ...able current load on each PDU before plugging the device into the PDU Balance the electrical current load between available PDUs Americas single phase PDU 1P30A 8C13 3C19UL P The following figure and table describes the specifications of the PDU Figure 1 Americas PDU for the Hitachi Universal V2 Rack Single phase PDU 1P30A 8C13 3C19UL P Part Number Region Phase Description 1P30A 8C13 3C19U L P Ame...

Page 109: ...ption 1P30A 15C13 3C19 UL P Americas Single 208V 30A 24A rated 60Hz 15 IEC C13 3 IEC C19 sockets NEMA L6 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 8C13 3C19UL P The following figure and table describes the specifications of the PDU Americas single phase PDU 1P30A 15C13 3C19UL P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storag...

Page 110: ...ted 60Hz 8 IEC C13 3 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 15C13 3C19UL P The following figure and table describes the specifications of the PDU Americas three phase PDU 3P30A 15C13 3C19UL P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G900 Hardware Reference Guide 110 ...

Page 111: ...ted 60Hz 15 IEC C13 3 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable Americas three phase PDU 3P30A 24C13 6C19UL P The following figure and table describes the specifications of the PDU Americas three phase PDU 3P30A 24C13 6C19UL P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G900 Hardware Reference Guide 111 ...

Page 112: ...0Hz 24 IEC C13 6 IEC C19 sockets NEMA L15 30P input power plug 4 5 m 14 76 feet cable APAC and EMEA single phase PDU 1P32A 9C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA single phase PDU 1P32A 9C13 3C19CE P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G900 Hardware Reference Guide 112 ...

Page 113: ...Hz 9 IEC C13 3 IEC C19 sockets IEC309 Blue 2P E input power plug 4 5 m 14 76 feet cable APAC and EMEA single phase PDU 1P32A 18C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA single phase PDU 1P32A 18C13 3C19CE P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G900 Hardware Reference Guide 113 ...

Page 114: ...60Hz 18 IEC C13 3 IEC C19 sockets IEC309 Blue 2P E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P16A 9C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P16A 9C13 3C19CE P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G900 Hardware Reference Guide 114 ...

Page 115: ...0Hz 9 IEC C13 3 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P16A 15C13 3C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P16A 15C13 3C19CE P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G900 Hardware Reference Guide 115 ...

Page 116: ...0Hz 15 IEC C13 3 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P The following figure and table describes the specifications of the PDU APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G900 Hardware Reference Guide 116 ...

Page 117: ...32A 24C13 6C19 CE P APAC and EMEA Three 400V max 3x 32A 50Hz 60Hz 24 IEC C13 6 IEC C19 sockets IEC309 Red 3P N E input power plug 4 5 m 14 76 feet cable APAC and EMEA three phase PDU 3P32A 24C13 6C19CE P Appendix E Power distribution units for Hitachi Universal V2 Rack Hitachi Virtual Storage Platform G900 Hardware Reference Guide 117 ...

Page 118: ...ck not toward each other The area behind the storage system and between the vertical 19 inch mounting posts must be free of PDUs and cable loops Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack The following tables list the rail kit information for the specified storage systems Table 23 Rail kits fo...

Page 119: ...e size and weight of the DB60 dense intermix drive trays used with VSP Gx00 models pay close special attention when mounted in third party racks When mounting DB60 dense intermix drive trays in third party racks observe the following guidelines and see the following figure Use anti tilt floor plates or ceiling mounted fixing brackets to stabilize the rack Use a rack that is at least 40 94 in 1040 ...

Page 120: ...Third party rack support for DB60 dense intermix drive trays Appendix F Non Hitachi racks Hitachi Virtual Storage Platform G900 Hardware Reference Guide 120 ...

Page 121: ... mark Explanation Do not disassemble the equipment Be careful when handling heavy equipment Use caution when handling electrostatic sensitive equipment and microcircuitry Avoid placing any non essential objects or equipment onto the storage system Use caution when handling the equipment Use caution when handling equipment with movable parts Use caution when handling equipment with hot surfaces Use...

Page 122: ...CBL controller CBL controller Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 122 ...

Page 123: ...Small form factor drive tray Small form factor drive tray Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 123 ...

Page 124: ...Large form factor drive tray Large form factor drive tray Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 124 ...

Page 125: ...Flash module drive tray Flash module drive tray Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 125 ...

Page 126: ...Dense intermix drive tray Dense intermix drive tray Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 126 ...

Page 127: ...CBL controller Dense intermix drive tray power supply CBL controller Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 127 ...

Page 128: ...dense intermix drive tray Battery Host port expansion chassis CMA used to secure dense intermix drive tray Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 128 ...

Page 129: ...PCIe switch board PCIe switch board Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 129 ...

Page 130: ...PCIe switch board Appendix G Warning labels on the storage system Hitachi Virtual Storage Platform G900 Hardware Reference Guide 130 ...

Page 131: ...product Recycling A nickel metal hydride battery is used in the Cache Backup Battery A nickel metal hydride battery is a resource that can be recycled When you want to replace the Cache Backup Battery call the service personnel They will dispose of it for you This nickel metal hydride battery which is designated as recycling product by a recycling promotion low must be recycled The mark posted on ...

Page 132: ... Regulatory compliance This equipment has been tested and certified for compliance with the following standards Appendix I Regulatory compliance Hitachi Virtual Storage Platform G900 Hardware Reference Guide 132 ...

Page 133: ...ic emission certifications EN55022 2010 CE marking EU EN55024 2010 EN61000 3 2 2006 A1 A2 EN61000 3 3 2013 Safety certifications UL and CSA 60950 1 2007 cTuVus United States of America and Canada EN60950 1 2006 A1 1 A1 A12 A2 TUV Germany IEC60950 1 2005 A 1 A2 N A All CB countries IEC60950 1 2005 A 1 A2 S_Mark Argentina TP TC 004 2011 EAC Russia CNS 14336 1 BSMI Taiwan EN60950 1 2006 A1 1 A1 A12 A...

Page 134: ... correct the interference at his own expense Testing was done with shielded cables Therefore in order to comply with the FCC regulations you must use shielded cables with your installation The electromagnetic interference EMI test was done in the following configuration If trouble occurs in another configuration a user might be requested to take appropriate preventative measures RKU CBL host port ...

Page 135: ...ara Corporate Headquarters 2845 Lafayette Street Santa Clara CA 95050 2639 USA HitachiVantara com community HitachiVantara com Contact Information USA 1 800 446 0744 Global 1 858 5474526 HitachiVantara com contact ...

Reviews: