4.
Organize the cables (see “Managing cables” on page 42).
5.
Verify the chassis and connector and port status using the
switchShow -qsfp
command. A sample of the command output is shown below. The example is
from a SAN384B-2 with a core blade installed in slot 3. Some details for the
SAN768B-2 will be different (such as the slot numbers) , but the reported
information for the QSFPs will be similar. Note that the State reported for an
unconnected QSFP (shown QSFP 0 and Ports 0-3 below) is No_SigDet. This is
different from the State of No_Synch that is reported for regular SFPs that are
unconnected. QSFP 7 (ports 3/28-3/31, Index 748-751) in the following example
shows the results for a connected QSFP.
switch:FID128:admin>
switchshow -qsfp
switchName: switch name
switchType: 121.3
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 75
switchId: fffc4b
switchWwn: 10:00:00:05:1e:4f:eb:00
zoning: ON (zoning name)
switchBeacon: OFF
FC Router: OFF
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Address Mode
0]
Index Slot Port QSFP Address Media Speed
State
Proto
=============================================================
256
3
0
0
------
id
16G
No_SigDet
FC
257
3
1
0
------
id
16G
No_SigDet
FC
258
3
2
0
------
id
16G
No_SigDet
FC
259
3
3
0
------
id
16G
No_SigDet
FC
260
3
4
1
------
--
16G
No_Module
FC
261
3
5
1
------
--
16G
No_Module
FC
262
3
6
1
------
--
16G
No_Module
FC
263
3
7
1
------
--
16G
No_Module
FC
264
3
8
2
------
--
16G
No_Module
FC
265
3
9
2
------
--
16G
No_Module
FC
266
3
10
2
------
--
16G
No_Module
FC
267
3
11
2
------
--
16G
No_Module
FC
268
3
12
3
------
--
16G
No_Module
FC
269
3
13
3
------
--
16G
No_Module
FC
270
3
14
3
------
--
16G
No_Module
FC
271
3
15
3
------
--
16G
No_Module
FC
736
3
16
4
------
--
16G
No_Module
FC
737
3
17
4
------
--
16G
No_Module
FC
738
3
18
4
------
--
16G
No_Module
FC
739
3
19
4
------
--
16G
No_Module
FC
740
3
20
5
------
--
16G
No_Module
FC
741
3
21
5
------
--
16G
No_Module
FC
742
3
22
5
------
--
16G
No_Module
FC
743
3
23
5
------
--
16G
No_Module
FC
744
3
24
6
------
--
16G
No_Module
FC
745
3
25
6
------
--
16G
No_Module
FC
746
3
26
6
------
--
16G
No_Module
FC
747
3
27
6
------
--
16G
No_Module
FC
748
3
28
7
------
id
16G
Online
FC E-Port
10:00:00:05:1e:39:e4:5a "trunkmaster name" (Trunk master)
749
3
29
7
------
id
16G
Online
FC E-Port
10:00:00:05:1e:39:e4:5a "trunkmaster name" (Trunk master)
750
3
30
7
------
id
16G
Online
FC E-Port
10:00:00:05:1e:39:e4:5a "trunkmaster name" (Trunk master)
751
3
31
7
------
id
16G
Online
FC E-Port
10:00:00:05:1e:39:e4:5a "trunkmaster name" (Trunk master)
Chapter 3. Starting and configuring the SAN768B-2
41
Summary of Contents for SAN768B-2
Page 2: ......
Page 10: ...viii SAN768B 2 Installation Service and User Guide...
Page 12: ...x SAN768B 2 Installation Service and User Guide...
Page 14: ...xii SAN768B 2 Installation Service and User Guide...
Page 26: ...xxiv SAN768B 2 Installation Service and User Guide...
Page 30: ...xxviii SAN768B 2 Installation Service and User Guide...
Page 96: ...66 SAN768B 2 Installation Service and User Guide...
Page 144: ...114 SAN768B 2 Installation Service and User Guide...
Page 152: ...122 SAN768B 2 Installation Service and User Guide...
Page 168: ...138 SAN768B 2 Installation Service and User Guide...
Page 180: ...150 SAN768B 2 Installation Service and User Guide...
Page 185: ......
Page 186: ...Part Number 99Y0730 Printed in USA GA32 0893 00 1P P N 99Y0730...