8.
Repeat steps 6 on page 316 and 7 on page 316 for the other rail.
9.
Tighten the assembly wing nuts on both rail assemblies.
Removing the power cable from the 2145 UPS-1U
You can remove the power cable from the 2145 UPS-1U if you are having problems with the power
supply and suspect that the power cable is defective.
Perform the following steps to remove the power cable:
1.
Remove the power from each SAN Volume Controller node. See MAP 5350 in the
IBM System Storage
SAN Volume Controller Troubleshooting Guide
for information about removing the power cable from the
SAN Volume Controller.
2.
Press and hold the on/off button
2
until the power light
1
is extinguished (approximately five
seconds). On some versions of the 2145 UPS-1U, you need a pointed device, such as a screwdriver, to
press the on/off button. The 2145 UPS-1U enters standby mode, with all indicators off. Figure 329 on
page 318 illustrates the front and rear views of the 2145 UPS-1U.
Figure 328. Securing the front rail on the 2145 UPS-1U
Chapter 2. Removing and replacing parts
317
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...