5.
Remove the air baffle (
1
in Figure 254). Grasp the air baffle by the leftmost and rightmost rear
corners and lift it up out of the node.
6.
Open the heat-exchanger-assembly release latch (
2
in Figure 254) to the fully open position.
7.
Lift the side of the heat-exchanger assembly (
3
in Figure 254) that is closer to the middle of the
node, slide it toward the middle of the node slightly, and lift the entire assembly out of the node.
8.
Open the microprocessor release latch to the fully open position.
Figure 254. SAN Volume Controller 2145-8A4 air baffle and heat-exchanger assembly
Chapter 2. Removing and replacing parts
255
Summary of Contents for SAN Volume Controller 2145-CG8