1
Microprocessor orientation indicator
2
Microprocessor
3
Microprocessor orientation indicator
4
Microprocessor connector
5
Microprocessor release lever
6.
Install a heat sink. If this is an original version of the SAN Volume Controller 2145-8G4 node, you
will install the other heat sink in step 7 on page 297.
a.
Apply thermal grease to the top of the microprocessor. Apply nine dots of thermal grease in three
rows of three dots each with the outer rows approximately 5 mm from the edge of the
microprocessor. The diameter of the cap from the thermal grease syringe is 5 mm, so you can use
it to judge the required position of the dots of thermal grease, as shown in Figure 297 on page
297.
1
2
3
4
5
svc00282
Figure 296. Installing the microprocessor
296
IBM SAN Volume Controller Hardware Maintenance Guide
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...