1
Power supply
2
Power-supply release tab
3
Power-supply handle
3.
Attach the cable-retention bracket to the power cord from the 2145 UPS-1U and connect the cord to
the power-cord connector on the power supply, as described in “Replacing the SAN Volume
Controller 2145-CG8 or 2145-CF8 cable-retention brackets” on page 39.
4.
If necessary, turn on the node.
5.
To the left of the power-cord connector on each power supply, verify that the ac power LED, as
shown by
1
in Figure 156 on page 166, and the dc power LED (
2
) are lit.
The green power LEDs indicate that the power supply is operating correctly. A power-supply error is
indicated by the amber power-supply error LED (
3
).
svc00543
2
1
3
Figure 155. SAN Volume Controller 2145-CG8 or 2145-CF8 power supply
Chapter 2. Removing and replacing parts
165