Removing the SAN Volume Controller 2145-8G4 Fibre Channel adapter assembly
Perform the following steps to remove the SAN Volume Controller 2145-8G4 Fibre Channel adapter
assembly:
1.
Turn off the node while ensuring that its data is mirrored and synchronized. See MAP 5350 in the
IBM System Storage SAN Volume Controller Troubleshooting Guide
for more information.
Attention:
When you install an adapter, make sure that the adapter is correctly seated in the
connector before you turn on the server. An incorrectly seated adapter might cause damage to the
system board, the riser-card assembly, or the adapter.
2.
When the node is completely turned off, remove the main power cable-retention bracket and remove
the power cable from the rear of the node.
3.
After writing down their locations, remove all other cables from the node.
4.
Remove the node from the rack and place it on a flat, static-protective surface. See “Removing the
SAN Volume Controller from a rack” on page 46.
5.
Remove the top cover. See “Removing the top cover” on page 77.
6.
Grasp the riser-card assembly (
2
in Figure 175) at the rear edge and lift to remove the riser-card
assembly.
7.
Place the riser-card assembly on a flat, static-protective surface.
8.
Carefully grasp the adapter
1
by its top edge or upper corners, and pull the adapter from the
riser-card assembly
2
.
svc00219
1
2
3
4
Figure 174. The physical port numbers for the SAN Volume Controller 2145-8G4
svc00255
1
2
Figure 175. Removing the riser-card assembly from the SAN Volume Controller 2145-8G4
182
IBM SAN Volume Controller Hardware Maintenance Guide
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...