Removing the SAN Volume Controller 2145-8G4 disk-drive backplane
Use the following information to remove the SAN Volume Controller 2145-8G4 disk-drive backplane.
To remove the SAN Volume Controller 2145-8G4 disk-drive backplane, including the SATA backplane,
complete the following steps:
1.
Read the safety precautions in “Safety and environmental notices” on page xiii.
2.
Turn off the node while ensuring that its data is mirrored and synchronized. See MAP 5350 in the
IBM System Storage SAN Volume Controller Troubleshooting Guide
for more information.
3.
Remove the cable-retention bracket and disconnect the power cable from the node. See “Removing the
cable-retention bracket” on page 34.
4.
Remove the node from the rack and place it on a flat, static-protective surface. See “Removing the
SAN Volume Controller from a rack” on page 46.
5.
Remove the service controller. See “Removing the service controller” on page 85.
6.
Pull the hard disk drive out of the node slightly to disengage it from the backplane.
7.
Remove the top cover. See “Removing the top cover” on page 77.
8.
Disconnect the two blue signal cables from the system board, shown in Figure 119 on page 133, and
disconnect the power cable from the power supply backplane card.
1
2
svc00482
Figure 118. SAN Volume Controller 2145-8A4 power supply connectors
132
IBM SAN Volume Controller Hardware Maintenance Guide
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...