![background image](http://html1.mh-extra.com/html/ibm/san-volume-controller-2145-cg8/san-volume-controller-2145-cg8_hardware-maintenance-manual_4016998226.webp)
1
10 Gbps Ethernet port 1
2
10 Gbps Ethernet port 2
3
Back-rail retaining screws
7.
Install both SFP transceivers into the Ethernet riser-card assembly, as described in “Removing and
replacing an Ethernet SFP transceiver” on page 189.
8.
If you did not do so as part of the procedure for replacing the Ethernet SFP transceivers, make sure
that all cables, adapters, and other components are installed and seated correctly and that you have
not left loose tools or parts inside the node. Make sure that all internal cables are correctly routed.
9.
If you did not do so as part of the procedure for replacing the Ethernet SFP transceivers, replace the
top cover, following the procedure in “Replacing the top cover” on page 81 and being careful to
reattach the fiber optic cable to Ethernet port 1 before replacing the serial cable connecting the node to
the UPS.
After following the procedure to replace the top cover, the node is installed in the rack, all cables are
reconnected, and the node is turned on.
Removing the high-speed SAS adapter
You can remove the high-speed adapter assembly in the SAN Volume Controller 2145-CF8.
2
3
1
Figure 193. SAN Volume Controller 2145-CG8 10 Gbps Ethernet riser-card assembly with cutaway view of back rail
196
IBM SAN Volume Controller Hardware Maintenance Guide
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...