7.
Install the hard disk drive. See “Replacing the disk drive” on page 118.
8.
Install the service controller. See “Replacing the service controller” on page 95.
9.
Replace the top cover. See “Replacing the top cover” on page 81.
10.
Place the node in the rack. See “Replacing the SAN Volume Controller in a rack” on page 55.
11.
Reconnect the Fibre Channel and Ethernet cables. Ensure that you replace the Fibre Channel and
Ethernet cables in the same ports from which they were removed.
12.
Turn on the node.
Replacing the SAN Volume Controller 2145-8G4 disk-drive backplane
To replace the SAN Volume Controller 2145-8G4 disk-drive backplane, including the SATA backplane,
complete the following steps.
1.
Connect the power cable to the replacement back plate.
2.
Slide the backplane into the mounting channels
2
, which are shown in Figure 129 on page 141,
making sure not to trap or pinch any nearby wires or cables.
Figure 128. SAN Volume Controller 2145-8A4 SATA cables
140
IBM SAN Volume Controller Hardware Maintenance Guide
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...