9.
Reconnect the Fibre Channel and Ethernet cables. Ensure that you replace the Fibre Channel and
Ethernet cables in the same ports from which they were removed.
10.
Turn on the node.
Removing the CMOS battery
You must remove the system board complementary metal-oxide semiconductor (CMOS), or system-board,
battery to replace it or to perform routine maintenance.
This product was designed with your safety in mind. The lithium battery must be handled correctly to
avoid possible danger. If you replace the battery, you must adhere to all safety instructions.
Use the reference numbers in parentheses at the end of each notice, such as (C003) for example, to find
the matching translated notice in
IBM System Storage SAN Volume Controller Safety Notices
.
Removing the SAN Volume Controller 2145-CG8 or 2145-CF8 CMOS battery
This topic describes how to remove the SAN Volume Controller 2145-CG8 or 2145-CF8 CMOS battery.
DANGER
Multiple power cords. The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords. (L003)
svc00322
1
2
or
1
2
svc00735
or
1
3
4
2
svc00734
CAUTION:
The battery contains lithium. To avoid possible explosion, do not burn or charge the battery.
Do not:
v
Throw or immerse into water
v
Heat to more than 100°C (212°F)
v
Repair or disassemble
Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local
regulations. In the United States, IBM has a process for the collection of this battery. For information,
call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C003)
This service action requires you to remove the cover and:
v
Turn the node off.
v
Disconnect the power cables.
v
Optionally disconnect the Fibre Channel and Ethernet data cables.
To remove the CMOS battery, perform the following steps:
142
IBM SAN Volume Controller Hardware Maintenance Guide
|
|
|
|
||
|
||
|
||
|
|
Summary of Contents for SAN Volume Controller 2145-CG8
Page 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 2: ......
Page 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 2 0 GC27 2283 00...
Page 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 24: ...xxii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 30: ...xxviii IBM SAN Volume Controller Hardware Maintenance Guide...
Page 54: ...24 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 362: ...332 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 364: ...334 IBM SAN Volume Controller Hardware Maintenance Guide...
Page 371: ......
Page 372: ...Part Number 31P1584 Printed in USA GC27 2283 00 1P P N 31P1584...