AC power-supply LEDs:
Use this information to view AC power-supply LEDs.
The following minimum configuration is required for the DC LED on the power
supply to be lit:
v
Power supply
v
Power cord
Note:
You must turn on the server for the DC LED on the power supply to be lit.
The following illustration shows the locations of the power-supply LEDs on the ac
power supply.
The following table describes the problems that are indicated by various
combinations of the power-supply LEDs on an ac power supply and suggested
actions to correct the detected problems.
AC power-supply LEDs
Description
Action
Notes
AC
DC
Error (!)
On
On
Off
Normal operation.
Off
Off
Off
No ac power to the
server or a problem
with the ac power
source.
1.
Check the ac power to the
server.
2.
Make sure that the power
cord is connected to a
functioning power source.
3.
Restart the server. If the error
remains, check the
power-supply LEDs.
4.
If the problem remains,
replace the power-supply.
This is a normal
condition when no ac
power is present.
Off
Off
On
The power supply
has failed.
Replace the power supply.
Off
On
Off
The power supply
has failed.
Replace the power supply.
Off
On
On
The power supply
has failed.
Replace the power supply.
Figure 89. AC power-supply LEDs
142
IBM System x3550 M4 Type 7914: Installation and Service Guide
Summary of Contents for Redboks System x3550 M4
Page 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 811: ...Taiwan Class A compliance statement Notices 793 ...
Page 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 819: ......
Page 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...