![IBM Redboks System x3550 M4 Installation And Service Manual Download Page 692](http://html.mh-extra.com/html/ibm/redboks-system-x3550-m4/redboks-system-x3550-m4_installation-and-service-manual_608587692.webp)
S.3050007
[S.3050007] A firmware fault has been detected in the UEFI image.
Explanation:
Internal UEFI Firmware Fault Detected, System halted
Severity:
Error
User response:
Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the system board.
S.3058004
[S.3058004] A Three Strike boot failure has occurred. The system has booted with default UEFI
settings.
Explanation:
POST failure has occurred! System booted with default settings.
Severity:
Error
User response:
Complete the following steps:
1.
This event resets UEFI to the default settings for the next boot. If successful, user is forced into F1 setup. Original
UEFI settings are still present.
2.
If User did not intentionally trigger the reboots, check logs for probable cause.
3.
Undo recent system changes (settings or devices added). If not recent system changes, remove all options then
remove CMOS battery for 30 seconds to clear CMOS contents. Verify that the system boots. Then, re-install
options one at a time to locate the problem.
4.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
5.
Reflash UEFI firmware.
6.
Remove and re-install CMOS battery for 30 seconds to clear CMOS contents
7.
(Trained service technician only) Replace the system board.
S.3060007
[S.3060007] A firmware fault has been detected in the UEFI image.
Explanation:
Internal UEFI Firmware Fault Detected, System halted
Severity:
Error
User response:
Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the system board.
S.3070007
[S.3070007] A firmware fault has been detected in the UEFI image.
Explanation:
Internal UEFI Firmware Fault Detected, System halted
Severity:
Error
User response:
Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the system board.
S.3050007 • S.3070007
674
IBM System x3550 M4 Type 7914: Installation and Service Guide
Summary of Contents for Redboks System x3550 M4
Page 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 811: ...Taiwan Class A compliance statement Notices 793 ...
Page 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 819: ......
Page 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...