![IBM Redboks System x3550 M4 Installation And Service Manual Download Page 432](http://html.mh-extra.com/html/ibm/redboks-system-x3550-m4/redboks-system-x3550-m4_installation-and-service-manual_608587432.webp)
800b0108-1301xxxx
Redundancy Lost for [RedundancySetElementName] has asserted. (Power Unit)
Explanation:
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b01081301xxxx or 0x800b01081301xxxx
Severity:
Error
Alert Category:
Critical - Redundant Power Supply
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0802
SNMP Trap ID:
9
Automatically notify Support:
No
User response:
1.
Check the LEDs for both power supplies.
2.
Follow the actions in Power-supply LEDs.
800b010a-1e81xxxx
Redundancy Lost for [RedundancySetElementName] has asserted. (Fan Zone 1)
Explanation:
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e81xxxx or 0x800b010a1e81xxxx
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0802
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Make sure that the connectors on fan n are not damaged.
2.
Make sure that the fan n connectors on the system board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010a-1e82xxxx
Redundancy Lost for [RedundancySetElementName] has asserted. (Fan Zone 2)
Explanation:
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e82xxxx or 0x800b010a1e82xxxx
Severity:
Error
Alert Category:
Critical - Fan Failure
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0802
SNMP Trap ID:
11
Automatically notify Support:
No
User response:
1.
Make sure that the connectors on fan n are not damaged.
2.
Make sure that the fan n connectors on the system board are not damaged.
3.
Make sure that the fans are correctly installed.
800b0108-1301xxxx • 800b010a-1e82xxxx
414
IBM System x3550 M4 Type 7914: Installation and Service Guide
Summary of Contents for Redboks System x3550 M4
Page 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...