201-901-003
Standalone Memory Test Failed
Explanation:
Memory Diagnostics Test Failed.
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Perform the actions mentioned one at a time and try the test after each action.
2.
If the problem remains, contact your technical-service representative.
3.
Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
4.
Make sure that DSA and BIOS/uEFI are at the latest level.
5.
Replace any DIMMS(s) mentioned in error, one by one.
6.
Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
7.
If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
DSA memory stress test results
The following messages can result when you run the memory stress test.
202-000-000
MemStr Test Passed
Explanation:
Test Passed.
Severity:
Event
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
202-801-000
MemStr Test Aborted
Explanation:
Internal program error.
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Turn off and restart the system.
2.
Make sure that the DSA Diagnostic code is at the latest level.
3.
Run the test again.
4.
If the system has stopped responding, turn off and restart the system.
5.
Check the system firmware level and upgrade if necessary.
6.
Run the memory diagnostic to identify the specific failing DIMM.
7.
If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for
the next corrective action.
201-901-003 • 202-801-000
758
IBM System x3550 M4 Type 7914: Installation and Service Guide
Summary of Contents for Redboks System x3550 M4
Page 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 2: ......
Page 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 811: ...Taiwan Class A compliance statement Notices 793 ...
Page 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Page 819: ......
Page 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...